CVE-2026-81861

Insufficiently Protected Credentials in Schneider Electric SCADA Pack allow Unauthorized RTU Access

Published Sep 11, 2026 CVSS 4.0 · 5.9 Medium EPSS < 1% KEV · Not listed
Description
CWE-522: Insufficiently Protected Credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality.

Analysis

AI-generated

Technical impact

This vulnerability is a CWE‑522 type credential exposure flaw that allows an attacker to obtain authentication information and gain unauthorized control of remote terminal unit (RTU) functions. The weakness arises when credentials are not sufficiently protected, potentially enabling an attacker to impersonate a legitimate user and manipulate RTU operations, which could compromise system integrity and safety.

Affected Systems

The affected products are Schneider Electric SCADAPack 32, SCADAPack 3xx, SCADAPack 470R, SCADAPack 47x, SCADAPack 47xd, SCADAPack 47xi, and SCADAPack 57x. No specific version information is provided in the source data.

Risk and Exploitability

The CVSS score of 5.9 indicates moderate severity. EPSS is not available, and the vulnerability is not listed in the CISA KEV catalog, suggesting no known widespread exploitation. The likely attack path involves intercepting or otherwise acquiring the exposed credentials to authenticate with RTU services, but the exact attack vector is not specified in the description, so this is inferred rather than explicitly stated.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Secure the storage of authentication credentials, for example by encrypting password files or using a secure credential vault
  • Change or remove any default or weak credentials and enforce strong password policies
  • Apply firmware or software updates released by Schneider Electric once they publish a patch that addresses the credential protection issue

Generated by OpenCVE AI on September 11, 2026 at 16:22 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
First Time appeared Schneider-electric
Schneider-electric scadapack 312e
Schneider-electric scadapack 32
Schneider-electric scadapack 470
Schneider-electric scadapack 570
Vendors & Products Schneider-electric
Schneider-electric scadapack 312e
Schneider-electric scadapack 32
Schneider-electric scadapack 470
Schneider-electric scadapack 570
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Insufficiently Protected Credentials in Schneider Electric SCADA Pack allow Unauthorized RTU Access
Type Values Removed Values Added
Description CWE-522: Insufficiently Protected Credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality.
Weaknesses CWE-522
References
Metrics cvssV4_0

{'score': 5.9, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N'}

Weaknesses
  • CWE-522

    Insufficiently Protected Credentials

Sources

Status
PUBLISHED
Assigner
schneider
Published
Updated
Sep 11, 2026, 7:14 PM
Reserved
Aug 27, 2026, 4:49 PM
Status
Awaiting Analysis
Published
Sep 11, 2026, 4:17 PM
Modified
Sep 18, 2026, 7:30 PM