Description
Progress MarkLogic Server 12.x releases before 12.1.0 and 11.x releases before 11.3.7 may record security-sensitive information in diagnostic logs under certain configurations. An attacker with access to the affected logs could use this information to obtain unauthorized access to protected resources.
Published: 2026-10-12
Score: 8.1 High
EPSS: < 1% Very Low
KEV: No
Impact: Sensitive data exposure through diagnostic logs
Action: Apply Patch
AI Analysis

Impact

Progress MarkLogic Server versions prior to 12.1.0 (12.x) and prior to 11.3.7 (11.x) can record security‑sensitive information such as credentials or tokens in trace and diagnostic logs when certain tracing configurations are enabled. An adversary who gains access to these logs could consume that data, potentially forging credentials or accessing protected resources without authorization. The flaw is identified as a log injection weakness with CWE‑532 describing the uncontrolled storage of sensitive information.

Affected Systems

The vulnerability affects Progress Software Corporation's MarkLogic Server. Versions 12.x that precede 12.1.0 and 11.x that precede 11.3.7 are impacted. Users of older or unpatched releases should ascertain the exact build and consult the vendor advisory for the appropriate update path.

Risk and Exploitability

A CVSS score of 8.1 indicates significant severity. The EPSS score is not available, and the vulnerability is not listed in the CISA KEV catalog. Exploitation requires local or delegated access to the system’s diagnostic log files, so the threat is most acute in environments where log files are not properly protected. If an attacker can read logs, the sensitivity of the exposed data could allow further unauthorized activity.

Generated by OpenCVE AI on October 12, 2026 at 16:21 UTC.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Upgrade MarkLogic Server to 12.1.0 or later, or to 11.3.7 or later
  • Restrict read access to diagnostic and trace log directories, ensuring only privileged accounts can view them
  • Disable or modify tracing configurations to exclude sensitive information from logs

Generated by OpenCVE AI on October 12, 2026 at 16:21 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories yet.

History

Fri, 16 Oct 2026 19:30:00 +0000

Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}


Mon, 12 Oct 2026 16:45:00 +0000

Type Values Removed Values Added
First Time appeared Progress Software Corporation
Progress Software Corporation marklogic Server
Vendors & Products Progress Software Corporation
Progress Software Corporation marklogic Server

Mon, 12 Oct 2026 15:45:00 +0000

Type Values Removed Values Added
Description Progress MarkLogic Server 12.x releases before 12.1.0 and 11.x releases before 11.3.7 may record security-sensitive information in diagnostic logs under certain configurations. An attacker with access to the affected logs could use this information to obtain unauthorized access to protected resources.
Title Sensitive information exposure in Progress MarkLogic Server trace logs
Weaknesses CWE-532
References
Metrics cvssV3_1

{'score': 8.1, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H'}


Subscriptions

Progress Software Corporation Marklogic Server
cve-icon MITRE

Status: PUBLISHED

Assigner: ProgressSoftware

Published:

Updated: 2026-10-16T17:40:16.383Z

Reserved: 2026-09-04T18:42:47.236Z

Link: CVE-2026-85949

cve-icon Vulnrichment

Updated: 2026-10-16T17:40:09.000Z

cve-icon NVD

Status : Awaiting Analysis

Published: 2026-10-12T16:17:06.303

Modified: 2026-10-16T18:19:28.280

Link: CVE-2026-85949

cve-icon Redhat

No data.

cve-icon OpenCVE Enrichment

Updated: 2026-10-12T16:30:14Z

Weaknesses
  • CWE-532

    Insertion of Sensitive Information into Log File