CVE-2026-86379

Published Oct 28, 2026 CVSS 3.1 · 7.2 High EPSS 2.8% KEV · Not listed
Description
Dell PowerProtect Data Domain Management Center, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.

Analysis

AI-generated

Technical impact

The vulnerability is a command injection flaw that can be triggered after the attacker obtains high privileged remote access to the Dell PowerProtect Data Domain Management Center. An attacker may execute arbitrary operating‑system commands, which can lead to full system compromise, data exfiltration, or denial of service.

Affected Systems

Dell PowerProtect Data Domain Management Center versions 7.7.1.0 through 8.8, LTS2024 release 7.13.1.0 to 7.13.1.80, LTS2025 release 8.3.1.0 to 8.3.1.40, and LTS2026 release 8.6.1.0 to 8.6.1.20 are affected.

Risk and Exploitability

The CVSS score of 7.2 indicates a high risk to confidentiality, integrity and availability. The EPSS score is 2% and the issue is not listed in CISA’s KEV catalog. The vulnerability requires an attacker to have high privileged remote access; therefore, it is unlikely to be exploited over the internet without prior compromise, but once present it can be leveraged for critical damage.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Install the Dell security update for PowerProtect Data Domain Management Center available from the Dell support site, which addresses the command injection flaw.
  • Restrict remote management access to trusted IP ranges or VPN‑only connections and disable any unnecessary remote services.
  • Apply least‑privilege principles by ensuring only essential accounts have high‑level privileges on the management console and monitor privileged activity logs for suspicious command execution.

Generated by OpenCVE AI on October 28, 2026 at 15:22 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Command Execution via OS Command Injection in Dell PowerProtect Data Domain Management Center
Type Values Removed Values Added
First Time appeared Dell
Dell powerprotect Data Domain Management Center
Vendors & Products Dell
Dell powerprotect Data Domain Management Center
Type Values Removed Values Added
Title Command Execution via OS Command Injection in Dell PowerProtect Data Domain Management Center
Type Values Removed Values Added
Description Dell PowerProtect Data Domain Management Center, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.
Weaknesses CWE-78
References
Metrics cvssV3_1

{'score': 7.2, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H'}

Weaknesses
  • CWE-78

    Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Sources

Status
PUBLISHED
Assigner
dell
Published
Updated
Oct 29, 2026, 10:45 AM
Reserved
Sep 7, 2026, 10:04 AM
Status
Awaiting Analysis
Published
Oct 28, 2026, 10:17 AM
Modified
Oct 29, 2026, 11:17 AM