CVE-2026-86396

Published Oct 28, 2026 CVSS 3.1 · 8.8 High EPSS 2.2% KEV · Not listed
Description
Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.

Analysis

AI-generated

Technical impact

A low‑privileged attacker with remote access can exploit an OS command injection flaw in Dell PowerProtect Data Domain, allowing execution of arbitrary system commands. This results in a full compromise of the affected system, potentially exposing sensitive data, altering configurations, or disrupting service availability.

Affected Systems

Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, and LTS2026 release versions 8.6.1.0 through 8.6.1.20 are vulnerable.

Risk and Exploitability

The flaw scores a CVSS base rating of 8.8, indicating high severity. An EPSS score of 2% indicates a small but non‑zero probability of exploitation, but the lack of a KEV listing does not diminish the risk posed by the vulnerability. Because the attack can be carried out by a low‑privileged remote user, the potential for exploitation is significant without stringent access controls.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Apply the Dell security update DSA‑2026‑416 provided for PowerProtect Data Domain to all affected installations.
  • If the update cannot be applied immediately, isolate the device from untrusted networks and restrict remote access to only essential, highly‑trusted administrators.
  • Monitor system logs and process activity for signs of unauthorized command execution, and review audit trails for insider or compromised user activity.

Generated by OpenCVE AI on October 28, 2026 at 15:23 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title OS Command Injection in Dell PowerProtect Data Domain Allows Remote Command Execution
Type Values Removed Values Added
First Time appeared Dell
Dell powerprotect Data Domain
Vendors & Products Dell
Dell powerprotect Data Domain
Type Values Removed Values Added
Title OS Command Injection in Dell PowerProtect Data Domain Allows Remote Command Execution
Type Values Removed Values Added
Description Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to command execution.
Weaknesses CWE-78
References
Metrics cvssV3_1

{'score': 8.8, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H'}

Weaknesses
  • CWE-78

    Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Sources

Status
PUBLISHED
Assigner
dell
Published
Updated
Oct 30, 2026, 5:18 PM
Reserved
Sep 7, 2026, 10:04 AM
Status
Undergoing Analysis
Published
Oct 28, 2026, 9:17 AM
Modified
Oct 30, 2026, 6:18 PM