Description
Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.

Analysis

AI-generated

Technical impact

An OS Command Injection vulnerability allows a high‑privileged remote attacker to execute arbitrary commands on Dell PowerProtect Data Domain systems. This can lead to complete system compromise, exposing sensitive data and enabling further lateral movement. The weakness stems from improper neutralization of special elements used in OS command construction.

Affected Systems

Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, and LTS2026 release versions 8.6.1.0 through 8.6.1.20 are affected.

Risk and Exploitability

The CVSS score of 7.2 indicates high severity. EPSS score of 2% indicates a moderate probability of exploitation, and the vulnerability is not listed in CISA KEV. The attacker must possess high‑privilege credentials and remote access to the target. Once compromised, the attacker can run any command on the host with the privileges of the vulnerable service, representing a significant risk for exposed systems.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Apply Dell’s official security update for PowerProtect Data Domain to the latest patch level.
  • Restrict remote administration access to trusted networks and enforce strong authentication mechanisms.
  • Configure least privilege for accounts that can access the Data Domain REST or CLI interfaces, and monitor audit logs for unexpected command execution.

Generated by OpenCVE AI on October 28, 2026 at 15:23 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'total'}, 'version': '2.0.3'}

Type Values Removed Values Added
Title Improper Neutralization Leading to Command Execution in Dell PowerProtect Data Domain
Type Values Removed Values Added
First Time appeared Dell
Dell powerprotect Data Domain
Vendors & Products Dell
Dell powerprotect Data Domain
Type Values Removed Values Added
Title Improper Neutralization Leading to Command Execution in Dell PowerProtect Data Domain
Type Values Removed Values Added
Description Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.
Weaknesses CWE-78
References
Metrics cvssV3_1

{'score': 7.2, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H'}

Weaknesses
  • CWE-78

    Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Sources

Status
PUBLISHED
Assigner
dell
Published
Updated
Oct 30, 2026, 5:18 PM
Reserved
Sep 7, 2026, 10:04 AM
Status
Undergoing Analysis
Published
Oct 28, 2026, 9:17 AM
Modified
Oct 30, 2026, 6:18 PM