CVE-2026-89202

Inadequate Authorization Enables Authenticated Attackers to Disconnect User Sessions in RUGGEDCOM CROSSBOW

Published Oct 13, 2026 CVSS 4.0 · 7.1 High EPSS < 1% KEV · Not listed
Description
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.

Analysis

AI-generated

Technical impact

Siemens RUGGEDCOM CROSSBOW devices have a flaw that allows authenticated users with minimal privileges to send disconnection requests for other users, including administrators. The device does not properly validate that the requester owns the session before terminating it, which results in a denial of service for the affected user. The vulnerability is rooted in an authorization bypass (CWE-639) and is limited to the local device session management function.

Affected Systems

All RUGGEDCOM CROSSBOW variants released before firmware version 6.0 are affected. The issue does not extend to later firmware releases and applies to both on‑premises and edge deployments of the product.

Risk and Exploitability

The vulnerability carries a CVSS score of 7.1, classifying it as high severity. Exploitation requires the attacker to be authenticated, although only minimal privileges are sufficient to trigger the disconnection. The EPSS score is not available, and the flaw is not listed in CISA’s KEV catalog, suggesting no widespread exploitation has been confirmed. Nonetheless, any attacker who gains access to the device can interrupt critical sessions, particularly those of administrators, which may impact operational continuity.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Upgrade the device firmware to version 6.0 or later to eliminate the vulnerable code path.
  • Restrict or disable the device disconnection functionality for accounts with non‑admin privileges to prevent arbitrary session termination.
  • Apply network segmentation or firewall rules to limit which hosts can reach the disconnection endpoints of the RUGGEDCOM CROSSBOW device.

Generated by OpenCVE AI on October 13, 2026 at 10:39 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
First Time appeared Siemens
Siemens ruggedcom Crossbow
Vendors & Products Siemens
Siemens ruggedcom Crossbow
Type Values Removed Values Added
Title Inadequate Authorization Enables Authenticated Attackers to Disconnect User Sessions in RUGGEDCOM CROSSBOW
Type Values Removed Values Added
Description A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V6.0). Affected devices do not properly perform authorization checks for device disconnection requests. This could allow an authenticated attacker with minimal privileges to disconnect active sessions of other users, including administrators, leading to a denial of service.
Weaknesses CWE-639
References
Metrics cvssV3_1

{'score': 6.5, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H'}

cvssV4_0

{'score': 7.1, 'vector': 'CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N'}

Weaknesses
  • CWE-639

    Authorization Bypass Through User-Controlled Key

Sources

Status
PUBLISHED
Assigner
siemens
Published
Updated
Oct 16, 2026, 5:17 PM
Reserved
Sep 11, 2026, 7:45 AM
Status
Awaiting Analysis
Published
Oct 13, 2026, 10:17 AM
Modified
Oct 16, 2026, 6:19 PM