CVE-2026-95765

Unauthenticated Sensitive Information Disclosure in Web-Based Management Interface of HPE Networking Fabric Composer

Published Nov 3, 2026 CVSS 3.1 · 5.4 Medium EPSS < 1% KEV · Not listed
Description
A sensitive information disclosure vulnerability exists in the web-based management interface of HPE Networking Fabric Composer. Successful exploitation could allow an unauthenticated remote attacker to obtain sensitive information.

Analysis

AI-generated

Technical impact

A vulnerability in the web-based management interface of HPE Networking Fabric Composer allows an unauthenticated remote attacker to obtain sensitive information. The weakness permits retrieval of potentially confidential configuration or operational data, exposing confidentiality without requiring prior authentication. According to the CVSS base score of 5.4, the impact falls into the moderate range, indicating that the disclosure can compromise sensitive information but does not provide attacker control or system compromise.

Affected Systems

The affected product is Hewlett Packard Enterprise Networking Fabric Composer. No specific affected version numbers are provided in the available data, so all deployed instances of Fabric Composer are potentially impacted until a patch is applied.

Risk and Exploitability

The CVSS score of 5.4 highlights moderate severity. The EPSS score is < 1%, and the vulnerability is not listed in CISA’s KEV catalog, suggesting that no widespread exploitation has been reported to date. The likely attack vector is remote access to the web interface over an unauthenticated session, which can be performed from any network host that can reach the management interface. Because authentication is not required, the threat model is expanded to anyone with network reach to the web interface, including internal and external actors.

Remediation

No solution or workaround provided in the CVE record.

OpenCVE Recommended Actions

  • Apply the latest HPE Networking Fabric Composer firmware or patch that resolves the sensitive information disclosure vulnerability.
  • Restrict network access to the web-based management interface to trusted IP addresses or subnet ranges and enforce firewall rules to limit unauthenticated traffic.
  • Disable or remove the web-based management interface from any servers that do not require it, or move the management service to a segregated management VLAN.
  • Ensure that sensitive configuration files and credentials are not exposed through the interface by reviewing configuration settings and access permissions.

Generated by OpenCVE AI on November 9, 2026 at 20:05 UTC.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Metrics ssvc

{'options': {'Automatable': 'no', 'Exploitation': 'none', 'Technical Impact': 'partial'}, 'version': '2.0.3'}

Type Values Removed Values Added
Weaknesses CWE-200
Type Values Removed Values Added
First Time appeared Hewlett Packard Enterprise (hpe)
Hewlett Packard Enterprise (hpe) fabric Composer
Hpe
Hpe fabric Composer
Vendors & Products Hewlett Packard Enterprise (hpe)
Hewlett Packard Enterprise (hpe) fabric Composer
Hpe
Hpe fabric Composer
Type Values Removed Values Added
Description A sensitive information disclosure vulnerability exists in the web-based management interface of HPE Networking Fabric Composer. Successful exploitation could allow an unauthenticated remote attacker to obtain sensitive information.
Title Unauthenticated Sensitive Information Disclosure in Web-Based Management Interface of HPE Networking Fabric Composer
References
Metrics cvssV3_1

{'score': 5.4, 'vector': 'CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N'}

Weaknesses
  • CWE-200

    Exposure of Sensitive Information to an Unauthorized Actor

Sources

Status
PUBLISHED
Assigner
hpe
Published
Updated
Nov 9, 2026, 5:51 PM
Reserved
Sep 22, 2026, 2:54 PM
Status
Awaiting Analysis
Published
Nov 3, 2026, 8:18 PM
Modified
Nov 9, 2026, 6:17 PM