| An issue was discovered in Infiray IRAY-A8Z3 1.0.957. The webserver contains an endpoint that can execute arbitrary commands by manipulating the cmd_string URL parameter. |
| The Omron SYSMAC Cx product family PLCs (CS series, CJ series, and CP series) through 2022-05-18 lack cryptographic authentication. They utilize the Omron FINS (9600/TCP) protocol for engineering purposes, including downloading projects and control logic to the PLC. This protocol has authentication flaws as reported in FSCT-2022-0057. Control logic is downloaded to PLC volatile memory using the FINS Program Area Read and Program Area Write commands or to non-volatile memory using other commands from where it can be loaded into volatile memory for execution. The logic that is loaded into and executed from the user program area exists in compiled object code form. Upon execution, these object codes are first passed to a dedicated ASIC that determines whether the object code is to be executed by the ASIC or the microprocessor. In the former case, the object code is interpreted by the ASIC whereas in the latter case the object code is passed to the microprocessor for object code interpretation by a ROM interpreter. In the abnormal case where the object code cannot be handled by either, an abnormal condition is triggered and the PLC is halted. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, thus allowing an attacker to manipulate transmitted object code to the PLC and either execute arbitrary object code commands on the ASIC or on the microprocessor interpreter. |
| The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module in the context of the runtime. In the case of at least the NJ series, an RTOS and hardware combination is used that would potentially allow for memory protection and privilege separation and thus limit the impact of code execution. However, it was not confirmed whether these sufficiently segment the runtime from the rest of the RTOS. |
| In Omron CS series, CJ series, and CP series PLCs through 2022-05-18, the password for access to the Web UI is stored in memory area D1449...D1452 and can be read out using the Omron FINS protocol without any further authentication. |
| Omron CS series, CJ series, and CP series PLCs through 2022-05-18 use cleartext passwords. They feature a UM Protection setting that allows users or system integrators to configure a password in order to restrict sensitive engineering operations (such as project/logic uploads and downloads). This password is set using the OMRON FINS command Program Area Protect and unset using the command Program Area Protect Clear, both of which are transmitted in cleartext. |
| The export function in SoftGuard Web (SGW) before 5.1.5 allows directory traversal to read an arbitrary local file via export or man.tcl. |
| SoftGuard Web (SGW) before 5.1.5 allows HTML injection. |
| Atmail 5.62 allows XSS via the mail/parse.php?file=html/$this-%3ELanguage/help/filexp.html&FirstLoad=1&HelpFile=file.html Search Terms field. |
| TZInfo is a Ruby library that provides access to time zone data and allows times to be converted using time zone rules. Versions prior to 0.36.1, as well as those prior to 1.2.10 when used with the Ruby data source tzinfo-data, are vulnerable to relative path traversal. With the Ruby data source, time zones are defined in Ruby files. There is one file per time zone. Time zone files are loaded with `require` on demand. In the affected versions, `TZInfo::Timezone.get` fails to validate time zone identifiers correctly, allowing a new line character within the identifier. With Ruby version 1.9.3 and later, `TZInfo::Timezone.get` can be made to load unintended files with `require`, executing them within the Ruby process. Versions 0.3.61 and 1.2.10 include fixes to correctly validate time zone identifiers. Versions 2.0.0 and later are not vulnerable. Version 0.3.61 can still load arbitrary files from the Ruby load path if their name follows the rules for a valid time zone identifier and the file has a prefix of `tzinfo/definition` within a directory in the load path. Applications should ensure that untrusted files are not placed in a directory on the load path. As a workaround, the time zone identifier can be validated before passing to `TZInfo::Timezone.get` by ensuring it matches the regular expression `\A[A-Za-z0-9+\-_]+(?:\/[A-Za-z0-9+\-_]+)*\z`. |
| containerd is an open source container runtime. A bug was found in the containerd's CRI implementation where programs inside a container can cause the containerd daemon to consume memory without bound during invocation of the `ExecSync` API. This can cause containerd to consume all available memory on the computer, denying service to other legitimate workloads. Kubernetes and crictl can both be configured to use containerd's CRI implementation; `ExecSync` may be used when running probes or when executing processes via an "exec" facility. This bug has been fixed in containerd 1.6.6 and 1.5.13. Users should update to these versions to resolve the issue. Users unable to upgrade should ensure that only trusted images and commands are used. |
| Sofia-SIP is an open-source Session Initiation Protocol (SIP) User-Agent library. Prior to version 1.13.8, an attacker can send a message with evil sdp to FreeSWITCH, which may cause crash. This type of crash may be caused by `#define MATCH(s, m) (strncmp(s, m, n = sizeof(m) - 1) == 0)`, which will make `n` bigger and trigger out-of-bound access when `IS_NON_WS(s[n])`. Version 1.13.8 contains a patch for this issue. |
| Use of hard-coded credentials vulnerability exists in STARDOM FCN Controller and FCJ Controller R4.10 to R4.31, which may allow an attacker with an administrative privilege to read/change configuration settings or update the controller with tampered firmware. |
| Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Windows) before build 29240 |
| Cleartext transmission of sensitive information. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240 |
| Open redirect via user-controlled query parameter. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240 |
| HTML injection via report name. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240 |
| Sensitive information disclosure due to insecure folder permissions. The following products are affected: Acronis Cyber Protect 15 (Linux) before build 29240, Acronis Agent (Linux) before build 28037 |
| A buffer overflow vulnerability in the Rubrik Backup Service (RBS) Agent for Linux or Unix-based systems in Rubrik CDM 7.0.1, 7.0.1-p1, 7.0.1-p2 or 7.0.1-p3 before CDM 7.0.2-p2 could allow a local attacker to obtain root privileges by sending a crafted message to the RBS agent. |
| An issue was discovered in Gentics CMS before 5.43.1. There is stored XSS in the profile description and in the username. |
| An issue was discovered in Gentics CMS before 5.43.1. By uploading a malicious ZIP file, an attacker is able to deserialize arbitrary data and hence can potentially achieve Java code execution. |