The HoYoVerse (formerly miHoYo) Genshin Impact mhyprot2.sys 1.0.0.0 anti-cheat driver does not adequately restrict unprivileged function calls, allowing local, unprivileged users to execute arbitrary code with SYSTEM privileges on Microsoft Windows systems. The mhyprot2.sys driver must first be installed by a user with administrative privileges.
Search vulnerabilities
Migrate queue importer - Moderately critical - Cross Site Request Forgery - SA-CONTRIB-2024-024
Cross-Site Request Forgery (CSRF) vulnerability in Drupal Migrate queue importer allows Cross Site Request Forgery.This issue affects Migrate queue importer: from 0.0.0 before 2.1.1.
Image Sizes - Moderately critical - Access bypass - SA-CONTRIB-2024-023
Insertion of Sensitive Information Into Sent Data vulnerability in Drupal Image Sizes allows Forceful Browsing.This issue affects Image Sizes: from 0.0.0 before 3.0.2.
Drupal REST & JSON API Authentication - Moderately critical - Access bypass - SA-CONTRIB-2024-022
Incorrect Authorization vulnerability in Drupal Drupal REST & JSON API Authentication allows Forceful Browsing.This issue affects Drupal REST & JSON API Authentication: from 0.0.0 before 2.0.13.
Commerce View Receipt - Moderately critical - Access bypass - SA-CONTRIB-2024-021
Incorrect Authorization vulnerability in Drupal Commerce View Receipt allows Forceful Browsing.This issue affects Commerce View Receipt: from 0.0.0 before 1.0.3.
Email Contact - Moderately critical - Access bypass - SA-CONTRIB-2024-020
Insufficient Granularity of Access Control vulnerability in Drupal Email Contact allows Forceful Browsing.This issue affects Email Contact: from 0.0.0 before 2.0.4.
Cortex XDR Agent: Improper Link Resolution Vulnerability When Generating a Tech Support File
An improper link resolution vulnerability in the Palo Alto Networks Cortex XDR agent on Windows devices allows a local attacker to read files on the system with elevated privileges when generating a tech support file.
Ignition Error Pages - Critical - Cross Site Scripting - SA-CONTRIB-2025-007
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Drupal Ignition Error Pages allows Cross-Site Scripting (XSS).This issue affects Ignition Error Pages: from 0.0.0 before 1.0.4.
AI (Artificial Intelligence) - Moderately critical - Access bypass, Information Disclosure - SA-CONTRIB-2025-004
Missing Authorization vulnerability in Drupal AI (Artificial Intelligence) allows Forceful Browsing.This issue affects AI (Artificial Intelligence): from 0.0.0 before 1.0.3.
A vulnerability exists in the ICCP stack of the affected SYS600 versions due to validation flaw in the process that establishes the ICCP communication. The validation flaw will cause a denial-of-service when ICCP of SYS600 is request to forward any da ...
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any data item updates with timestamps too distant in the future to any remote ICCP system. By default, ICCP is not configured and not enabled. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10.2 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
A vulnerability exists in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS ...
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
AI (Artificial Intelligence) - Critical - Cross Site Request Forgery - SA-CONTRIB-2025-003
Cross-Site Request Forgery (CSRF) vulnerability in Drupal AI (Artificial Intelligence) allows Cross Site Request Forgery.This issue affects AI (Artificial Intelligence): from 1.0.0 before 1.0.2.
A vulnerability exists during the start of the affected SYS600, where an input validation flaw causes a buffer-overflow while reading a specific configuration file. Subsequently SYS600 will fail to start. The configuration file can only be accessed by ...
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
POST SMTP Mailer < 2.5.7 - Account Takeover via CSRF
The POST SMTP Mailer WordPress plugin before 2.5.7 does not have proper CSRF checks in some AJAX actions, which could allow attackers to make logged in users with the manage_postman_smtp capability resend an email to an arbitrary address (for example a password reset email could be resent to an attacker controlled email, and allow them to take over an account).
POST SMTP Mailer < 2.7.1 - Unauthenticated Cross-site Scripting
The POST SMTP Mailer WordPress plugin before 2.7.1 does not escape email message content before displaying it in the backend, allowing an unauthenticated attacker to perform XSS attacks against highly privileged users.
WordPress POST SMTP Mailer plugin <= 2.8.6 - Broken Access Control on API vulnerability
Missing Authorization vulnerability in Post SMTP Post SMTP Mailer/Email Log.This issue affects Post SMTP Mailer/Email Log: from n/a through 2.8.6.
A vulnerability exists in the handling of a malformed IEC 104 TCP packet. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected conne ...
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
A missing authorization in Fortinet FortiManager versions 7.2.0 through 7.2.1, and versions 7.0.0 through 7.0.7 may allow an authenticated attacker to overwrite global threat feeds via crafted update requests.
FreeScout Vulnerable to Stored XSS
FreeScout is a free self-hosted help desk and shared mailbox. Prior to version 1.8.180, the application is vulnerable to Cross-Site Scripting (XSS) attacks due to incorrect input validation and sanitization of user-input data when an authenticated user updates the profile of an arbitrary customer. This issue has been patched in version 1.8.180.
SourceCodester Health Center Patient Record Management System admin.php sql injection
A vulnerability, which was classified as critical, has been found in SourceCodester Health Center Patient Record Management System 1.0. Affected by this issue is some unknown functionality of the file /admin/admin.php. The manipulation of the argument Username leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.