| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The affected product allows firmware updates to be downloaded from EG4's
website, transferred via USB dongles, or installed through EG4's
Monitoring Center (remote, cloud-connected interface) or via a serial
connection, and can install these files without integrity checks. The
TTComp archive format used for the firmware is unencrypted and can be
unpacked and altered without detection. |
| An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact. |
| A flaw has been found in projectsend up to r1720. Impacted is an unknown function of the component File Editor/Custom Download Aliases. This manipulation causes cross site scripting. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version r1945 is recommended to address this issue. Patch name: 334da1ea39cb12f6b6e98dd2f80bb033e0c7b845. It is advisable to upgrade the affected component. |
| Use of client-side authentication issue exists in CHOCO TEI WATCHER mini (IB-MCT001) all versions. If this issue is exploited, a remote attacker may obtain the product login password without authentication. |
| A vulnerability classified as problematic was found in Drivin Soluções up to 20250226. This vulnerability affects unknown code of the file /api/school/registerSchool of the component API Handler. The manipulation of the argument message leads to cross site scripting. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution.
Honeywell recommends updating to the most recent version of Honeywell Experion PKS:
520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1.
The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3. |
| A vulnerability was identified in newbee-mall-plus up to 2.4.1. This vulnerability affects the function executeSeckill of the file /seckillExecution/. The manipulation of the argument userid leads to authorization bypass. It is possible to initiate the attack remotely. The attack is considered to have high complexity. It is stated that the exploitability is difficult. The exploit is publicly available and might be used. |
| The WorkExaminer Professional server installation comes with an FTP server that is used to receive the client logs on TCP port 12304. An attacker with network access to this port can use weak hardcoded credentials to login to the FTP server and modify or read data, log files and gain remote code execution as NT Authority\SYSTEM on the server by exchanging accessible service binaries in the WorkExaminer installation directory (e.g. "C:\Program File (x86)\Work Examiner Professional Server"). |
| The Telenium Online Web Application is vulnerable due to a PHP endpoint accessible to unauthenticated network users that improperly handles user-supplied input. This vulnerability occurs due to the insecure termination of a regular expression check within the endpoint. Because the input is not correctly validated or sanitized, an unauthenticated attacker can inject arbitrary operating system commands through a crafted HTTP request, leading to remote code execution on the server in the context of the web application service account. |
| An attacker could exploit this vulnerability by uploading arbitrary
files via the a specific endpoint, leading to unauthorized remote code
execution or system compromise. |
| A flaw has been found in Harness 3.3.0. This impacts the function LookupRepo of the file app/api/controller/gitspace/lookup_repo.go. Executing manipulation of the argument url can lead to server-side request forgery. The attack may be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in kuaifan DooTask up to 1.2.49. Affected by this vulnerability is an unknown functionality of the file app/Http/Controllers/Api/UsersController.php. The manipulation of the argument keys[department] results in sql injection. The attack can be executed remotely. The exploit has been made public and could be used. |
| There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.
Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities.
Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y). |
| veraPDF is an open source PDF/A validation library. Executing policy checks using custom schematron files via the CLI invokes an XSL transformation that may theoretically lead to a remote code execution (RCE) vulnerability. This doesn't affect the standard validation and policy checks functionality, veraPDF's common use cases. Most veraPDF users don't insert any custom XSLT code into policy profiles, which are based on Schematron syntax rather than direct XSL transforms. For users who do, only load custom policy files from sources you trust. This issue has not yet been patched. Users are advised to be cautious of XSLT code until a patch is available. |
| ** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DNS-120, DNR-202L, DNS-315L, DNS-320, DNS-320L, DNS-320LW, DNS-321, DNR-322L, DNS-323, DNS-325, DNS-326, DNS-327L, DNR-326, DNS-340L, DNS-343, DNS-345, DNS-726-4, DNS-1100-4, DNS-1200-05 and DNS-1550-04 up to 20240812. It has been classified as critical. This affects the function sprintf of the file /cgi-bin/photocenter_mgr.cgi. The manipulation of the argument filter leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced. |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| A vulnerability, which was classified as problematic, has been found in OcoMon 4.0RC1/4.0/5.0RC1. This issue affects some unknown processing of the file /includes/common/require_access_recovery.php of the component URL Handler. The manipulation leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 4.0.1 and 5.0 is able to address this issue. It is recommended to upgrade the affected component. |
| A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user. |
| The protocol used for remote linking over RF for End-of-Train and
Head-of-Train (also known as a FRED) relies on a BCH checksum for packet
creation. It is possible to create these EoT and HoT packets with a
software defined radio and issue brake control commands to the EoT
device, disrupting operations or potentially overwhelming the brake
systems. |
| A flaw has been found in DinukaNavaratna Dee Store 1.0. Affected is an unknown function. Executing manipulation can lead to missing authorization. The attack may be performed from remote. The exploit has been published and may be used. Multiple endpoints are affected. |