Search Results (360678 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-20991 1 Fibaro 4 Home Center 2, Home Center 2 Firmware, Home Center Lite and 1 more 2024-11-21 9.8 Critical
In Fibaro Home Center 2 and Lite devices with firmware version 4.540 and older an authenticated user can run commands as root user using a command injection vulnerability.
CVE-2021-20990 1 Fibaro 4 Home Center 2, Home Center 2 Firmware, Home Center Lite and 1 more 2024-11-21 7.5 High
In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode.
CVE-2021-20989 1 Fibaro 4 Home Center 2, Home Center 2 Firmware, Home Center Lite and 1 more 2024-11-21 5.9 Medium
Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older initiate SSH connections to the Fibaro cloud to provide remote access and remote support capabilities. This connection can be intercepted using DNS spoofing attack and a device initiated remote port-forward channel can be used to connect to the web management interface. Knowledge of authorization credentials to the management interface is required to perform any further actions.
CVE-2021-20988 2 Hilscher, Pepperl-fuchs 17 Rcx Rtos, Ice1-16di-g60l-v1d, Ice1-16di-g60l-v1d Firmware and 14 more 2024-11-21 8.6 High
In Hilscher rcX RTOS versions prios to V2.1.14.1 the actual UDP packet length is not verified against the length indicated by the packet. This may lead to a denial of service of the affected device.
CVE-2021-20987 2 Hilscher, Pepperl-fuchs 23 Ethernet\/ip Adapter, Ethernet\/ip Adapter Firmware, Pcv100-f200-b25-v1d-6011 and 20 more 2024-11-21 8.6 High
A denial of service and memory corruption vulnerability was found in Hilscher EtherNet/IP Core V2 prior to V2.13.0.21that may lead to code injection through network or make devices crash without recovery.
CVE-2021-20986 2 Hilscher, Pepperl-fuchs 73 Profinet Io Device, Profinet Io Device Firmware, Ohv-f230-b17 and 70 more 2024-11-21 7.5 High
A Denial of Service vulnerability was found in Hilscher PROFINET IO Device V3 in versions prior to V3.14.0.7. This may lead to unexpected loss of cyclic communication or interruption of acyclic communication.
CVE-2021-20877 1 Canon 34 2204f, 2204n, 2206if and 31 more 2024-11-21 4.8 Medium
Cross-site scripting vulnerability in Canon laser printers and small office multifunctional printers (LBP162L/LBP162, MF4890dw, MF269dw/MF265dw/MF264dw/MF262dw, MF249dw/MF245dw/MF244dw/MF242dw/MF232w, and MF229dw/MF224dw/MF222dw sold in Japan, imageCLASS MF Series (MF113W/MF212W/MF217W/MF227DW/MF229DW, MF232W/MF244DW/MF247DW/MF249DW, MF264DW/MF267DW/MF269DW/MF269DW VP, and MF4570DN/MF4570DW/MF4770N/MF4880DW/MF4890DW) and imageCLASS LBP Series (LBP113W/LBP151DW/LBP162DW ) sold in the US, and iSENSYS (LBP162DW, LBP113W, LBP151DW, MF269dw, MF267dw, MF264dw, MF113w, MF249dw, MF247dw, MF244dw, MF237w, MF232w, MF229dw, MF217w, MF212w, MF4780w, and MF4890dw) and imageRUNNER (2206IF, 2204N, and 2204F) sold in Europe) allows remote attackers to inject an arbitrary script via unspecified vectors.
CVE-2021-20876 1 Groupsession 1 Groupsession 2024-11-21 6.8 Medium
Path traversal vulnerability in GroupSession Free edition ver5.1.1 and earlier, GroupSession byCloud ver5.1.1 and earlier, and GroupSession ZION ver5.1.1 and earlier allows an attacker with an administrative privilege to obtain sensitive information stored in the hierarchy above the directory on the published site's server via unspecified vectors.
CVE-2021-20875 1 Groupsession 1 Groupsession 2024-11-21 6.1 Medium
Open redirect vulnerability in GroupSession Free edition ver5.1.1 and earlier, GroupSession byCloud ver5.1.1 and earlier, and GroupSession ZION ver5.1.1 and earlier allows a remote unauthenticated attacker to redirect users to arbitrary web sites and conduct phishing attacks by having a user to access a specially crafted URL.
CVE-2021-20874 1 Groupsession 1 Groupsession 2024-11-21 7.5 High
Incorrect permission assignment for critical resource vulnerability in GroupSession Free edition ver5.1.1 and earlier, GroupSession byCloud ver5.1.1 and earlier, and GroupSession ZION ver5.1.1 and earlier allows a remote unauthenticated attacker to access arbitrary files on the server and obtain sensitive information via unspecified vectors.
CVE-2021-20873 1 Yappli 1 Yappli 2024-11-21 8.1 High
Yappli is an application development platform which provides the function to access a requested URL using Custom URL Scheme. When Android apps are developed with Yappli versions since v7.3.6 and prior to v9.30.0, they are vulnerable to improper authorization in Custom URL Scheme handler, and may be directed to unintended sites via a specially crafted URL.
CVE-2021-20872 1 Konicaminolta 104 Bizhub 224e, Bizhub 224e Firmware, Bizhub 227 and 101 more 2024-11-21 6.8 Medium
Protection mechanism failure vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier) allows a physical attacker to bypass the firmware integrity verification and to install malicious firmware.
CVE-2021-20871 1 Konicaminolta 160 Bizhub 224e, Bizhub 224e Firmware, Bizhub 226i and 157 more 2024-11-21 6.5 Medium
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain the credentials if the destination information including credentials are registered in the address book via a specific SOAP message.
CVE-2021-20870 1 Konicaminolta 174 Bizhub 224e, Bizhub 224e Firmware, Bizhub 226i and 171 more 2024-11-21 4.6 Medium
Improper handling of exceptional conditions vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, bizhub 4752/4052 GC9-X4 and earlier, bizhub C3850/C3350/3850FS, bizhub 4750/4050, bizhub C3110, bizhub C3100P) allows a physical attacker to obtain unsent scanned image data when scanned data transmission is stopped due to the network error by ejecting a HDD before the scan job times out.
CVE-2021-20869 1 Konicaminolta 160 Bizhub 224e, Bizhub 224e Firmware, Bizhub 226i and 157 more 2024-11-21 6.5 Medium
Exposure of sensitive information to an unauthorized actor vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain some of user credentials if LDAP server authentication is enabled via a specific SOAP message.
CVE-2021-20868 1 Konicaminolta 160 Bizhub 224e, Bizhub 224e Firmware, Bizhub 226i and 157 more 2024-11-21 4.5 Medium
Incorrect authorization vulnerability in KONICA MINOLTA bizhub series (bizhub C750i G00-35 and earlier, bizhub C650i/C550i/C450i G00-B6 and earlier, bizhub C360i/C300i/C250i G00-B6 and earlier, bizhub 750i/650i/550i/450i G00-37 and earlier, bizhub 360i/300i G00-33 and earlier, bizhub C287i/C257i/C227i G00-19 and earlier, bizhub 306i/266i/246i/226i G00-B6 and earlier, bizhub C759/C659 GC7-X8 and earlier, bizhub C658/C558/C458 GC7-X8 and earlier, bizhub 958/808/758 GC7-X8 and earlier, bizhub 658e/558e/458e GC7-X8 and earlier, bizhub C287/C227 GC7-X8 and earlier, bizhub 287/227 GC7-X8 and earlier, bizhub 368e/308e GC7-X8 and earlier, bizhub C368/C308/C258 GC9-X4 and earlier, bizhub 558/458/368/308 GC9-X4 and earlier, bizhub C754e/C654e GDQ-M0 and earlier, bizhub 754e/654e GDQ-M0 and earlier, bizhub C554e/C454e GDQ-M1 and earlier, bizhub C364e/C284e/C224e GDQ-M1 and earlier, bizhub 554e/454e/364e/284e/224e GDQ-M1 and earlier, bizhub C754/C654 C554/C454 GR1-M0 and earlier, bizhub C364/C284/C224 GR1-M0 and earlier, bizhub 754/654 GR1-M0 and earlier, bizhub C4050i/C3350i/C4000i/C3300i G00-B6 and earlier, bizhub C3320i G00-B6 and earlier, bizhub 4750i/4050i G00-22 and earlier, bizhub 4700i G00-22 and earlier, bizhub C3851FS/C3851/C3351 GC9-X4 and earlier, and bizhub 4752/4052 GC9-X4 and earlier) allows an attacker on the adjacent network to obtain user credentials if external server authentication is enabled via a specific SOAP message sent by an administrative user.
CVE-2021-20867 1 Advancedcustomfields 1 Advanced Custom Fields 2024-11-21 6.5 Medium
Advanced Custom Fields versions prior to 5.11 and Advanced Custom Fields Pro versions prior to 5.11 contain a missing authorization vulnerability in moving the field group which may allow a user to move the unauthorized field group via unspecified vectors.
CVE-2021-20866 1 Advancedcustomfields 1 Advanced Custom Fields 2024-11-21 6.5 Medium
Advanced Custom Fields versions prior to 5.11 and Advanced Custom Fields Pro versions prior to 5.11 contain a missing authorization vulnerability in obtaining the user list which may allow a user to obtain the unauthorized information via unspecified vectors.
CVE-2021-20865 1 Advancedcustomfields 1 Advanced Custom Fields 2024-11-21 7.5 High
Advanced Custom Fields versions prior to 5.11 and Advanced Custom Fields Pro versions prior to 5.11 contain a missing authorization vulnerability in browsing database which may allow a user to browse unauthorized data via unspecified vectors.
CVE-2021-20864 1 Elecom 28 Edwrc-2533gst2, Edwrc-2533gst2 Firmware, Wrc-1167gst2 and 25 more 2024-11-21 8.8 High
Improper access control vulnerability in ELECOM routers (WRC-1167GST2 firmware v1.25 and prior, WRC-1167GST2A firmware v1.25 and prior, WRC-1167GST2H firmware v1.25 and prior, WRC-2533GS2-B firmware v1.52 and prior, WRC-2533GS2-W firmware v1.52 and prior, WRC-1750GS firmware v1.03 and prior, WRC-1750GSV firmware v2.11 and prior, WRC-1900GST firmware v1.03 and prior, WRC-2533GST firmware v1.03 and prior, WRC-2533GSTA firmware v1.03 and prior, WRC-2533GST2 firmware v1.25 and prior, WRC-2533GST2SP firmware v1.25 and prior, WRC-2533GST2-G firmware v1.25 and prior, and EDWRC-2533GST2 firmware v1.25 and prior) allows a network-adjacent unauthenticated attacker to bypass access restriction, and to start the telnet service and execute an arbitrary OS command via unspecified vectors.