Show plain JSON{"containers": {"cna": {"affected": [{"product": "Fibaro Home Center", "vendor": "Fibar Group S.A", "versions": [{"lessThanOrEqual": "4.600", "status": "affected", "version": "Home Center 2", "versionType": "custom"}, {"lessThanOrEqual": "4.600", "status": "affected", "version": "Home Center Lite", "versionType": "custom"}]}], "credits": [{"lang": "en", "value": "Marton Illes IoT Inspector Research Lab https://www.iot-inspector.com"}], "datePublic": "2021-04-15T00:00:00", "descriptions": [{"lang": "en", "value": "In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2022-09-30T09:15:17", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE"}, "references": [{"tags": ["x_refsource_CONFIRM"], "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"}, {"name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center", "tags": ["mailing-list", "x_refsource_FULLDISC"], "url": "http://seclists.org/fulldisclosure/2021/Apr/27"}, {"tags": ["x_refsource_MISC"], "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"}], "source": {"discovery": "EXTERNAL"}, "title": "Fibaro Home Center Unauthenticated access to shutdown, reboot and reboot to recovery mode", "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2021-04-15T10:00:00.000Z", "ID": "CVE-2021-20990", "STATE": "PUBLIC", "TITLE": "Fibaro Home Center Unauthenticated access to shutdown, reboot and reboot to recovery mode"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "Fibaro Home Center", "version": {"version_data": [{"version_affected": "<=", "version_name": "Home Center 2", "version_value": "4.600"}, {"version_affected": "<=", "version_name": "Home Center Lite", "version_value": "4.600"}]}}]}, "vendor_name": "Fibar Group S.A"}]}}, "credit": [{"lang": "eng", "value": "Marton Illes IoT Inspector Research Lab https://www.iot-inspector.com"}], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "In Fibaro Home Center 2 and Lite devices with firmware version 4.600 and older an internal management service is accessible on port 8000 and some API endpoints could be accessed without authentication to trigger a shutdown, a reboot or a reboot into recovery mode."}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "impact": {"cvss": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-306 Missing Authentication for Critical Function"}]}]}, "references": {"reference_data": [{"name": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/", "refsource": "CONFIRM", "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"}, {"name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center", "refsource": "FULLDISC", "url": "http://seclists.org/fulldisclosure/2021/Apr/27"}, {"name": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"}]}, "source": {"discovery": "EXTERNAL"}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T17:53:23.099Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"}, {"name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center", "tags": ["mailing-list", "x_refsource_FULLDISC", "x_transferred"], "url": "http://seclists.org/fulldisclosure/2021/Apr/27"}, {"tags": ["x_refsource_MISC", "x_transferred"], "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"}]}]}, "cveMetadata": {"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2021-20990", "datePublished": "2021-04-19T14:05:02.510969Z", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-09-16T16:42:28.116Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}