| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to obtain and disclose sensitive data information or cause the device to crash on the OPC UA Tunneller (versions prior to 6.3.0.8233). |
| The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code on the OPC UA Tunneller (versions prior to 6.3.0.8233). |
| The affected product has uncontrolled resource consumption issues, which may allow an attacker to cause a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233). |
| Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior has a type confusion issue while processing project files, which may allow an attacker to execute arbitrary code. |
| Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code. |
| In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an information disclosure vulnerability in the ventilator allows attackers with physical access to the configuration interface's logs to get valid checksums for tampered configuration files. |
| Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code. |
| An untrusted pointer dereference has been identified in the way TPEditor(v1.98 and prior) processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. |
| Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code. |
| TPEditor (v1.98 and prior) is vulnerable to two out-of-bounds write instances in the way it processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. |
| In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files. |
| A stack-based buffer overflow may exist in Delta Electronics CNCSoft ScreenEditor versions 1.01.26 and prior when processing specially crafted project files, which may allow an attacker to execute arbitrary code. |
| A use after free issue has been identified in the way ISPSoft(v3.12 and prior) processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution. |
| In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface. |
| Delta Electronics DOPSoft Version 4.0.8.21 and prior has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code. |
| SOOIL Developments Co Ltd DiabecareRS,AnyDana-i & AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i & AnyDana-A mobile apps doesn't use adequate measures to authenticate the communicating entities before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the authentication sequence via Bluetooth Low Energy. |
| Delta Electronics DOPSoft Version 4.0.8.21 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code. |
| Some parsing functions in the affected product do not check the return value of malloc and the thread handling the message is forced to close, which may lead to a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233). |
| SOOIL Developments CoLtd DiabecareRS, AnyDana-i, AnyDana-A, The communication protocol of the insulin pump and AnyDana-i,AnyDana-A mobile apps doesn't use adequate measures to authenticate the pump before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the keys and spoof the pump via BLE. |
| SOOIL Developments CoLtd DiabecareRS, AnyDana-i ,AnyDana-A, communication protocol of the insulin pump & AnyDana-i,AnyDana-A mobile apps doesnt use adequate measures to protect encryption keys in transit which allows unauthenticated physically proximate attacker to sniff keys via (BLE). |