Filtered by vendor Honeywell
Subscriptions
Total
92 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-1309 | 1 Honeywell | 1 Niagara Framework | 2024-11-22 | 6.5 Medium |
Uncontrolled Resource Consumption vulnerability in Honeywell Niagara Framework on Windows, Linux, QNX allows Content Spoofing.This issue affects Niagara Framework: before Niagara AX 3.8.1, before Niagara 4.1. | ||||
CVE-2023-6179 | 1 Honeywell | 1 Prowatch | 2024-11-21 | 7.8 High |
Honeywell ProWatch, 4.5, including all Service Pack versions, contain a Vulnerability in Application Server's executable folder(s). A(n) attacker could potentially exploit this vulnerability, leading to a standard user to have arbitrary system code execution. Honeywell recommends updating to the most recent version of this product, service or offering (Pro-watch 6.0.2, 6.0, 5.5.2,5.0.5). | ||||
CVE-2023-5390 | 1 Honeywell | 4 Controledge Unit Operations Controller, Controledge Unit Operations Controller Firmware, Controledge Virtual Unit Operations Controller and 1 more | 2024-11-21 | 5.3 Medium |
An attacker could potentially exploit this vulnerability, leading to files being read from the Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC. This exploit could be used to read files from the controller that may expose limited information from the device. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-5389 | 1 Honeywell | 4 Controledge Unit Operations Controller, Controledge Unit Operations Controller Firmware, Controledge Virtual Unit Operations Controller and 1 more | 2024-11-21 | 9.1 Critical |
An attacker could potentially exploit this vulnerability, leading to the ability to modify files on Honeywell Experion ControlEdge VirtualUOC and ControlEdge UOC . This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-51603 | 1 Honeywell | 1 Saia Pg5 Controls Suite | 2024-11-21 | N/A |
Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of CAB files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18592. | ||||
CVE-2023-51602 | 1 Honeywell | 1 Saia Pg5 Controls Suite | 2024-11-21 | N/A |
Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18591. | ||||
CVE-2023-51599 | 1 Honeywell | 1 Saia Pg5 Controls Suite | 2024-11-21 | N/A |
Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18412. | ||||
CVE-2023-3712 | 1 Honeywell | 2 Pm43, Pm43 Firmware | 2024-11-21 | 6.6 Medium |
Files or Directories Accessible to External Parties vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Privilege Escalation.This issue affects PM43 versions prior to P10.19.050004. Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006). | ||||
CVE-2023-3711 | 1 Honeywell | 2 Pm43, Pm43 Firmware | 2024-11-21 | 6.4 Medium |
Session Fixation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Session Credential Falsification through Prediction.This issue affects PM43 versions prior to P10.19.050004. Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006). | ||||
CVE-2023-3710 | 1 Honeywell | 13 Pc23 43, Pd43, Pm23 43 and 10 more | 2024-11-21 | 9.9 Critical |
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injection.This issue affects PM43 versions prior to P10.19.050004. Update to the latest available firmware version of the respective printers to version MR19.5 (e.g. P10.19.050006). | ||||
CVE-2023-3243 | 1 Honeywell | 2 Alerton Bcm-web, Alerton Bcm-web Firmware | 2024-11-21 | 8.3 High |
** UNSUPPORTED WHEN ASSIGNED ** [An attacker can capture an authenticating hash and utilize it to create new sessions. The hash is also a poorly salted MD5 hash, which could result in a successful brute force password attack. Impacted product is BCM-WEB version 3.3.X. Recommended fix: Upgrade to a supported product such as Alerton ACM.] Out of an abundance of caution, this CVE ID is being assigned to better serve our customers and ensure all who are still running this product understand that the product is end of life and should be removed or upgraded. | ||||
CVE-2023-26597 | 1 Honeywell | 2 C300, C300 Firmware | 2024-11-21 | 7.5 High |
Controller DoS due to buffer overflow in the handling of a specially crafted message received by the controller. See Honeywell Security Notification for recommendations on upgrading and versioning. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-25948 | 1 Honeywell | 4 Direct Station, Engineering Station, Experion Server and 1 more | 2024-11-21 | 7.5 High |
Server information leak of configuration data when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-25770 | 1 Honeywell | 2 C300, C300 Firmware | 2024-11-21 | 9.8 Critical |
Controller DoS may occur due to buffer overflow when an error is generated in response to a specially crafted message. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-25178 | 1 Honeywell | 2 C300, C300 Firmware | 2024-11-21 | 9.8 Critical |
Controller may be loaded with malicious firmware which could enable remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-25078 | 1 Honeywell | 4 Direct Station, Engineering Station, Experion Server and 1 more | 2024-11-21 | 9.8 Critical |
Server or Console Station DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-24480 | 1 Honeywell | 2 C300, C300 Firmware | 2024-11-21 | 9.8 Critical |
Controller DoS due to stack overflow when decoding a message from the server. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-24474 | 1 Honeywell | 4 Direct Station, Engineering Station, Experion Server and 1 more | 2024-11-21 | 7.5 High |
Experion server may experience a DoS due to a heap overflow which could occur when handling a specially crafted message | ||||
CVE-2023-23585 | 1 Honeywell | 4 Direct Station, Engineering Station, Experion Server and 1 more | 2024-11-21 | 9.8 Critical |
Experion server DoS due to heap overflow occurring during the handling of a specially crafted message for a specific configuration operation. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
CVE-2023-22435 | 1 Honeywell | 4 Direct Station, Engineering Station, Experion Server and 1 more | 2024-11-21 | 7.5 High |
Experion server may experience a DoS due to a stack overflow when handling a specially crafted message. |