Search Results (365444 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-34527 1 Cloudorc 1 Solidui 2026-04-15 7.5 High
spaces_plugin/app.py in SolidUI 0.4.0 has an unnecessary print statement for an OpenAI key. The printed string might be logged.
CVE-2025-3020 2026-04-15 5.4 Medium
An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.
CVE-2023-47771 2026-04-15 8.3 High
Missing Authorization vulnerability in ThemePunch OHG Essential Grid.This issue affects Essential Grid: from n/a through 3.0.18.
CVE-2025-30187 1 Powerdns 1 Dnsdist 2026-04-15 3.7 Low
In some circumstances, when DNSdist is configured to use the nghttp2 library to process incoming DNS over HTTPS queries, an attacker might be able to cause a denial of service by crafting a DoH exchange that triggers an unbounded I/O read loop, causing an unexpected consumption of CPU resources.
CVE-2025-66071 2 Tychesoftwares, Wordpress 2 Custom Order Numbers For Woocommerce, Wordpress 2026-04-15 5.3 Medium
Missing Authorization vulnerability in tychesoftwares Custom Order Numbers for WooCommerce custom-order-numbers-for-woocommerce allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Custom Order Numbers for WooCommerce: from n/a through <= 1.11.0.
CVE-2024-34490 2026-04-15 5.1 Medium
In Maxima through 5.47.0 before 51704c, the plotting facilities make use of predictable names under /tmp. Thus, the contents may be controlled by a local attacker who can create files in advance with these names. This affects, for example, plot2d.
CVE-2024-46627 1 Becn 1 Datagerry 2026-04-15 9.1 Critical
Incorrect access control in BECN DATAGERRY v2.2 allows attackers to execute arbitrary commands via crafted web requests.
CVE-2024-46242 2026-04-15 7.5 High
An issue in the validate_email function in CTFd/utils/validators/__init__.py of CTFd 3.7.3 allows attackers to cause a Regular expression Denial of Service (ReDoS) via supplying a crafted string as e-mail address during registration.
CVE-2025-66053 2 Kriesi, Wordpress 2 Enfold, Wordpress 2026-04-15 6.5 Medium
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Kriesi Enfold enfold allows Stored XSS.This issue affects Enfold: from n/a through <= 7.1.2.
CVE-2024-39309 1 Parse Community 1 Parse Server 2026-04-15 9.8 Critical
Parse Server is an open source backend that can be deployed to any infrastructure that can run Node.js. A vulnerability in versions prior to 6.5.7 and 7.1.0 allows SQL injection when Parse Server is configured to use the PostgreSQL database. The algorithm to detect SQL injection has been improved in versions 6.5.7 and 7.1.0. No known workarounds are available.
CVE-2025-41438 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
CVE-2025-40935 1 Siemens 20 Ruggedcom Rmc8388, Ruggedcom Rs416pv2, Ruggedcom Rs416v2 and 17 more 2026-04-15 4.3 Medium
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.1), RUGGEDCOM RSG907R (All versions < V5.10.1), RUGGEDCOM RSG908C (All versions < V5.10.1), RUGGEDCOM RSG909R (All versions < V5.10.1), RUGGEDCOM RSG910C (All versions < V5.10.1), RUGGEDCOM RSG920P V5.X (All versions < V5.10.1), RUGGEDCOM RSL910 (All versions < V5.10.1), RUGGEDCOM RST2228 (All versions < V5.10.1), RUGGEDCOM RST2228P (All versions < V5.10.1), RUGGEDCOM RST916C (All versions < V5.10.1), RUGGEDCOM RST916P (All versions < V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device.
CVE-2021-47902 1 Testa 1 Online Test Management System 2026-04-15 8.2 High
Testa Online Test Management System 3.4.7 contains a SQL injection vulnerability that allows attackers to manipulate database queries through the 'q' search parameter. Attackers can inject malicious SQL code in the search field to extract database information, potentially accessing sensitive user or system data.
CVE-2024-28141 2026-04-15 6.3 Medium
The web application is not protected against cross-site request forgery attacks. Therefore, an attacker can trick users into performing actions on the application when they visit an attacker-controlled website or click on a malicious link. E.g. an attacker can forge malicious links to reset the admin password or create new users.
CVE-2025-40801 1 Siemens 8 Comos, Nx, Simcenter 3d and 5 more 2026-04-15 8.1 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2021-46686 2026-04-15 N/A
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in acmailer CGI ver.4.0.3 and earlier and acmailer DB ver.1.1.5 and earlier. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker.
CVE-2025-40800 1 Siemens 6 Comos, Nx, Simcenter 3d and 3 more 2026-04-15 7.4 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2025-26262 2026-04-15 6.5 Medium
An issue in the component /internals/functions of R-fx Networks Linux Malware Detect v1.6.5 allows attackers to escalate privileges and execute arbitrary code via supplying a file that contains a crafted filename.
CVE-2025-40344 1 Linux 1 Linux Kernel 2026-04-15 7.0 High
In the Linux kernel, the following vulnerability has been resolved: ASoC: Intel: avs: Disable periods-elapsed work when closing PCM avs_dai_fe_shutdown() handles the shutdown procedure for HOST HDAudio stream while period-elapsed work services its IRQs. As the former frees the DAI's private context, these two operations shall be synchronized to avoid slab-use-after-free or worse errors.