Search Results (386321 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-8834 1 Jcg 1 Link-net 2026-04-15 2.4 Low
A vulnerability has been found in JCG Link-net LW-N915R 17s.20.001.908. Affected is an unknown function of the file /wireless/basic.asp of the component Wireless Basic Settings Page. The manipulation of the argument Network Name leads to cross site scripting. It is possible to launch the attack remotely.
CVE-2024-0130 2026-04-15 8.8 High
NVIDIA UFM Enterprise, UFM Appliance, and UFM CyberAI contain a vulnerability where an attacker can cause an improper authentication issue by sending a malformed request through the Ethernet management interface. A successful exploit of this vulnerability might lead to escalation of privileges, data tampering, denial of service, and information disclosure.
CVE-2024-44540 1 Ubiquiti 1 Airmax Firmware 2026-04-15 6.6 Medium
Ubiquiti AirMax firmware version firmware version 8 allows attackers with physical access to gain a privileged command shell via the UART Debugging Port.
CVE-2025-64253 1 Wordpress 2 Health Check & Troubleshooting, Wordpress 2026-04-15 4.9 Medium
Path Traversal: '.../...//' vulnerability in WordPress.org Health Check & Troubleshooting health-check allows Path Traversal.This issue affects Health Check & Troubleshooting: from n/a through <= 1.7.1.
CVE-2024-28138 2026-04-15 7.3 High
An unauthenticated attacker with network access to the affected device's web interface can execute any system command via the "msg_events.php" script as the www-data user. The HTTP GET parameter "data" is not properly sanitized.
CVE-2025-4393 2026-04-15 6.5 Medium
Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a binary payload to crash the service or elevate privileges. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025
CVE-2024-36107 1 Minio 1 Minio 2026-04-15 5.3 Medium
MinIO is a High Performance Object Storage released under GNU Affero General Public License v3.0. `If-Modified-Since` and `If-Unmodified-Since` headers when used with anonymous requests by sending a random object name requests can be used to determine if an object exists or not on the server on a specific bucket and also gain access to some amount of information such as `Last-Modified (of the latest version)`, `Etag (of the latest version)`, `x-amz-version-id (of the latest version)`, `Expires (metadata value of the latest version)`, `Cache-Control (metadata value of the latest version)`. This conditional check was being honored before validating if the anonymous access is indeed allowed on the metadata of an object. This issue has been addressed in commit `e0fe7cc3917`. Users must upgrade to RELEASE.2024-05-27T19-17-46Z for the fix. There are no known workarounds for this issue.
CVE-2025-30518 1 Intel 1 Gametechdev Presentmon 2026-04-15 6.7 Medium
Incorrect default permissions for some Intel(R) PresentMon before version 2.3.1 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2024-30896 1 Influxdata 1 Influxdb 2026-04-15 9.1 Critical
InfluxDB OSS 2.x through 2.7.11 stores the administrative operator token under the default organization which allows authorized users with read access to the authorization resource of the default organization to retrieve the operator token. InfluxDB OSS 1.x, Enterprise, Cloud, Cloud Dedicated and Clustered are not affected. NOTE: The researcher states that InfluxDB allows allAccess administrators to retrieve all raw tokens via an "influx auth ls" command. The supplier indicates that the organizations feature is operating as intended and that users may choose to add users to non-default organizations. A future release of InfluxDB 2.x will remove the ability to retrieve tokens from the API. The supplier has stated that InfluxDB 2.8.0 has addressed this issue.
CVE-2025-23180 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2025-23179 2026-04-15 5.5 Medium
CWE-798: Use of Hard-coded Credentials
CVE-2025-11488 1 D-link 1 Dir-852 2026-04-15 7.3 High
A weakness has been identified in D-Link DIR-852 up to 20251002. This affects an unknown part of the file /HNAP1/. Executing manipulation can lead to command injection. The attack may be launched remotely. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-41378 2026-04-15 N/A
The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel.
CVE-2024-29214 1 Redhat 6 Enterprise Linux, Rhel Aus, Rhel E4s and 3 more 2026-04-15 7.5 High
Improper input validation in UEFI firmware CseVariableStorageSmm for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2022-31491 2 Voltronic Power, Voltronicpower 2 Viewpower Pro, Viewpower 2026-04-15 10 Critical
Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this to run arbitrary code immediately regardless of any managed UPS state or presence.
CVE-2022-30636 2026-04-15 7.5 High
httpTokenCacheKey uses path.Base to extract the expected HTTP-01 token value to lookup in the DirCache implementation. On Windows, path.Base acts differently to filepath.Base, since Windows uses a different path separator (\ vs. /), allowing a user to provide a relative path, i.e. .well-known/acme-challenge/..\..\asd becomes ..\..\asd. The extracted path is then suffixed with +http-01, joined with the cache directory, and opened. Since the controlled path is suffixed with +http-01 before opening, the impact of this is significantly limited, since it only allows reading arbitrary files on the system if and only if they have this suffix.
CVE-2024-51722 1 Blackberry 1 Secusuite 2026-04-15 6.4 Medium
A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands.
CVE-2025-62155 1 Quantumnous 1 New-api 2026-04-15 8.5 High
New API is a large language mode (LLM) gateway and artificial intelligence (AI) asset management system. Prior to version 0.9.6, a recently patched SSRF vulnerability contains a bypass method that can bypass the existing security fix and still allow SSRF to occur. Because the existing fix only applies security restrictions to the first URL request, a 302 redirect can bypass existing security measures and successfully access the intranet. This issue has been patched in version 0.9.6.
CVE-2024-4601 1 Socomec 1 Net Vision 2026-04-15 6.7 Medium
An incorrect authentication vulnerability has been found in Socomec Net Vision affecting version 7.20. This vulnerability allows an attacker to perform a brute force attack on the application and recover a valid session, because the application uses a five-digit integer value.
CVE-2025-27211 1 Ui 1 Edgeswitch 2026-04-15 7.5 High
An Improper Input Validation in EdgeMAX EdgeSwitch (Version 1.10.4 and earlier) could allow a Command Injection by a malicious actor with access to EdgeSwitch adjacent network.