| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Sourcecodester Online Grading System 1.0 is affected by a Cross Site Request Forgery vulnerability due to a lack of CSRF protection. This could lead to an attacker tricking the administrator into executing arbitrary code via a crafted HTML page, as demonstrated by a Create User action at the admin/modules/user/controller.php?action=add URI. |
| In Phoenix SCT WinFlash 1.1.12.0 through 1.5.74.0, the included drivers could be used by a malicious Windows application to gain elevated privileges. Adverse impacts are limited to the Windows environment and there is no known direct impact to the UEFI firmware. This was fixed in late June 2019. |
| When executing VideoLAN VLC media player 3.0.8 with libqt on Windows, Data from a Faulting Address controls Code Flow starting at libqt_plugin!vlc_entry_license__3_0_0f+0x00000000003b9aba. NOTE: the VideoLAN security team indicates that they have not been contacted, and have no way of reproducing this issue. |
| A flaw was found in HAProxy before 2.0.6. In legacy mode, messages featuring a transfer-encoding header missing the "chunked" value were not being correctly rejected. The impact was limited but if combined with the "http-reuse always" setting, it could be used to help construct an HTTP request smuggling attack against a vulnerable component employing a lenient parser that would ignore the content-length header as soon as it saw a transfer-encoding one (even if not entirely valid according to the specification). |
| OSIsoft PI Vision, All versions of PI Vision prior to 2019. The affected product is vulnerable to an improper access control, which may return unauthorized tag data when viewing analysis data reference attributes. |
| OSIsoft PI Vision, PI Vision 2017 R2 and PI Vision 2017 R2 SP1. The affected product is vulnerable to cross-site scripting, which may allow invalid input to be introduced. |
| OSIsoft PI Vision, All versions of PI Vision prior to 2019. The affected product is vulnerable to a cross-site request forgery that may be introduced on the PI Vision administration site. |
|
Omron’s CS and CJ series PLCs have an unrestricted externally accessible lock vulnerability.
|
| An issue was found in GE S2020/S2020G Fast Switch 61850, S2020/S2020G Fast Switch 61850 Versions 07A03 and prior. An attacker can inject arbitrary Javascript in a specially crafted HTTP request that may be reflected back in the HTTP response. The device is also vulnerable to a stored cross-site scripting vulnerability that may allow session hijacking, disclosure of sensitive data, cross-site request forgery (CSRF) attacks, and remote code execution. |
| An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016-August 2018), Veradius Unity (718132) with ViewForum option (shipped between 2016-August 2018), Pulsera (718095) and Endura (718075) with wireless option (shipped between 26-June-2017 through 07-August 2018), Pulsera (718095) and Endura (718075) with ViewForum option (shipped between 26-June-2017 through 07-August 2018). The router software uses an encryption scheme that is not strong enough for the level of protection required. |
| In Omron PLC CS series, all versions, Omron PLC CJ series, all versions, and Omron PLC NJ series, all versions, the software does not implement sufficient measures to prevent multiple failed authentication attempts within in a short time frame, making it more susceptible to brute force attacks. |
| In Omron PLC CJ series, all versions and Omron PLC CS series, all versions, an attacker could spoof arbitrary messages or execute commands. |
| In Advantech DiagAnywhere Server, Versions 3.07.11 and prior, multiple stack-based buffer overflow vulnerabilities exist in the file transfer service listening on the TCP port. Successful exploitation could allow an unauthenticated attacker to execute arbitrary code with the privileges of the user running DiagAnywhere Server. |
| BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit. |
| HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation. |
| BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest. An attacker with physical access to the CardioMessenger can disclose medical measurement data and the serial number from the implanted cardiac device the CardioMessenger is paired with. |
| An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior) outside the intended directory. |
| BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure. |
| In Omron CX-Supervisor, Versions 3.5 (12) and prior, Omron CX-Supervisor ships with Teamviewer Version 5.0.8703 QS. This version of Teamviewer is vulnerable to an obsolete function vulnerability requiring user interaction to exploit. |
| In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device. |