CVE Vendors Products Updated CVSS v3.1
CVE-2019-10953 5 Abb, Phoenixcontact, Schneider-electric and 2 more 20 Pm554-tp-eth, Pm554-tp-eth Firmware, Ilc 151 Eth and 17 more 2026-05-29 7.5 High
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
CVE-2008-2474 1 Abb 1 Pcu400 2026-04-23 N/A
Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.
CVE-2025-3756 1 Abb 4 800xa System, Symphony + Operations, Symphony Plus Mr (melody Rack) and 1 more 2026-04-17 6.5 Medium
A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.  The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.     This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.
CVE-2024-13928 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 7.2 High
SQL injection vulnerabilities in ASPECT allow unintended access and manipulation of database repositories if session administrator credentials become compromised. This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03.
CVE-2024-0335 1 Abb 3 Symphony Plus S\+ Analyst, Symphony Plus S\+ Engineering, Symphony Plus S\+ Operations 2026-04-15 7.5 High
ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst) This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2.
CVE-2025-8754 1 Abb 1 Zenon 2026-04-15 7.5 High
Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14.
CVE-2025-5517 1 Abb 8 Terra Ac Wallbox Ce Juno, Terra Ac Wallbox Ce Juno Firmware, Terra Ac Wallbox Ce Mid and 5 more 2026-04-15 6.8 Medium
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (MID/ CE) -Terra AC MID, ABB Terra AC wallbox (MID/ CE) -Terra AC Juno CE, ABB Terra AC wallbox (MID/ CE) -Terra AC PTB, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): through 1.8.32; Terra AC wallbox (UL32A): through 1.8.2; Terra AC wallbox (MID/ CE) -Terra AC MID: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC Juno CE: through 1.8.32; Terra AC wallbox (MID/ CE) -Terra AC PTB: through 1.8.21; Terra AC wallbox (JP): through 1.8.2.
CVE-2021-22291 1 Abb 2 Eibport V3 Knx, Eibport V3 Knx Gsm 2026-04-15 8 High
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in ABB EIBPORT V3 KNX, ABB EIBPORT V3 KNX GSM.This issue affects EIBPORT V3 KNX: before 3.9.2; EIBPORT V3 KNX GSM: before 3.9.2.
CVE-2025-6072 1 Abb 2 Rmc-100, Rmc-100-lite 2026-04-15 7.5 High
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and CVE-2025-6074 is exploited, the attacker can use the JSON configuration to overflow the date of expiration field.This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
CVE-2024-48842 1 Abb 1 Flxeon 2026-04-15 7 High
Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions
CVE-2025-10205 1 Abb 1 Flxeon 2026-04-15 8.8 High
Use of a One-Way Hash with a Predictable Salt vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. and newer versions
CVE-2025-6071 1 Abb 2 Rmc-100, Rmc-100-lite 2026-04-15 5.3 Medium
Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. An attacker can gain access to salted information to decrypt MQTT information. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
CVE-2024-48851 1 Abb 1 Flxeon 2026-04-15 7.2 High
Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation. This issue affects FLXEON: through 9.3.5.
CVE-2025-6074 1 Abb 2 Rmc-100, Rmc-100-lite 2026-04-15 6.5 Medium
Use of Hard-coded Cryptographic Key vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to source code and control network, the attacker can bypass the REST interface authentication and gain access to MQTT configuration data. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
CVE-2025-6073 1 Abb 2 Rmc-100, Rmc-100-lite 2026-04-15 7.5 High
Stack-based Buffer Overflow vulnerability in ABB RMC-100, ABB RMC-100 LITE. When the REST interface is enabled by the user, and an attacker gains access to the control network, and user/password broker authentication is enabled, and CVE-2025-6074 is exploited, the attacker can overflow the buffer for username or password. This issue affects RMC-100: from 2105457-043 through 2105457-045; RMC-100 LITE: from 2106229-015 through 2106229-016.
CVE-2025-10207 1 Abb 1 Flxeon 2026-04-15 7.2 High
Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5.
CVE-2025-12142 1 Abb 1 Terra Ac Wallbox Jp 2026-04-15 6.1 Medium
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
CVE-2025-10504 1 Abb 1 Terra Ac Wallbox Jp 2026-04-15 6.1 Medium
Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
CVE-2024-9639 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 8 High
Remote Code Execution vulnerabilities are present in ASPECT if session administra-tor credentials become compromised. This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03.
CVE-2024-13948 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 7.3 High
Windows permissions for ASPECT configuration toolsets are not fully secured allow-ing exposure of configuration informationThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.