Filtered by vendor Ni
Subscriptions
Total
29 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-6806 | 1 Ni | 1 Veristand | 2024-11-21 | 9.8 Critical |
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access Project resources. These missing checks may result in remote code execution. This affects NI VeriStand 2024 Q2 and prior versions. | ||||
CVE-2024-6805 | 1 Ni | 1 Veristand | 2024-11-21 | 7.5 High |
The NI VeriStand Gateway is missing authorization checks when an actor attempts to access File Transfer resources. These missing checks may result in information disclosure or remote code execution. This affects NI VeriStand 2024 Q2 and prior versions. | ||||
CVE-2024-6794 | 1 Ni | 1 Veristand | 2024-11-21 | 9.8 Critical |
A deserialization of untrusted data vulnerability exists in NI VeriStand Waveform Streaming Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions. | ||||
CVE-2024-6793 | 1 Ni | 1 Veristand | 2024-11-21 | 9.8 Critical |
A deserialization of untrusted data vulnerability exists in NI VeriStand DataLogging Server that may result in remote code execution. Successful exploitation requires an attacker to send a specially crafted message. These vulnerabilities affect NI VeriStand 2024 Q2 and prior versions. | ||||
CVE-2024-6791 | 1 Ni | 1 Veristand | 2024-11-21 | 7.8 High |
A directory path traversal vulnerability exists when loading a vsmodel file in NI VeriStand that may result in remote code execution. Successful exploitation requires an attacker to get a user to open a specially crafted .vsmodel file. This vulnerability affects VeriStand 2024 Q2 and prior versions. | ||||
CVE-2024-6122 | 1 Ni | 2 Flexlogger, Systemlink | 2024-11-21 | 5.5 Medium |
An incorrect permission in the installation directory for the shared NI SystemLink Server KeyValueDatabase service may result in information disclosure via local access. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service. | ||||
CVE-2024-6121 | 1 Ni | 2 Flexlogger, Systemlink | 2024-11-21 | 7.8 High |
An out-of-date version of Redis shipped with NI SystemLink Server is susceptible to multiple vulnerabilities, including CVE-2022-24834. This affects NI SystemLink Server 2024 Q1 and prior versions. It also affects NI FlexLogger 2023 Q2 and prior versions which installed this shared service. | ||||
CVE-2024-4081 | 1 Ni | 1 Labview | 2024-11-21 | 7.8 High |
A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects NI LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2024-4080 | 1 Ni | 1 Labview | 2024-11-21 | 7.8 High |
A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2024-4079 | 1 Ni | 1 Labview | 2024-11-21 | 7.8 High |
An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2024-23612 | 1 Ni | 1 Labview | 2024-11-21 | 7.8 High |
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2024-23609 | 1 Ni | 1 Labview | 2024-11-21 | 7.8 High |
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2023-5136 | 1 Ni | 4 Diadem, Flexlogger, Topografix Data Plugin and 1 more | 2024-11-21 | 5.5 Medium |
An incorrect permission assignment in the TopoGrafix DataPlugin for GPX could result in information disclosure. An attacker could exploit this vulnerability by getting a user to open a specially crafted data file. | ||||
CVE-2023-4601 | 2 Microsoft, Ni | 2 Windows, System Configuration | 2024-11-21 | 8.1 High |
A stack-based buffer overflow vulnerability exists in NI System Configuration that could result in information disclosure and/or arbitrary code execution. Successful exploitation requires that an attacker can provide a specially crafted response. This affects NI System Configuration 2023 Q3 and all previous versions. | ||||
CVE-2023-4570 | 1 Ni | 1 Measurementlink | 2024-11-21 | 8.8 High |
An improper access restriction in NI MeasurementLink Python services could allow an attacker on an adjacent network to reach services exposed on localhost. These services were previously thought to be unreachable outside of the node. This affects measurement plug-ins written in Python using version 1.1.0 of the ni-measurementlink-service Python package and all previous versions. | ||||
CVE-2022-42718 | 1 Ni | 1 Labview Command Line Interface | 2024-11-21 | 7.8 High |
Incorrect default permissions in the installation folder for NI LabVIEW Command Line Interface (CLI) may allow an authenticated user to potentially enable escalation of privilege via local access. | ||||
CVE-2022-35415 | 1 Ni | 1 Configuration Manager | 2024-11-21 | 7.8 High |
An improper input validation in NI System Configuration Manager before 22.5 may allow a privileged user to potentially enable escalation of privilege via local access. | ||||
CVE-2022-27237 | 1 Ni | 5 Flexlogger, G Web Development Software, Labview and 2 more | 2024-11-21 | 6.1 Medium |
There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later. | ||||
CVE-2021-42563 | 2 Microsoft, Ni | 2 Windows, Ni Service Locator | 2024-11-21 | 7.8 High |
There is an Unquoted Service Path in NI Service Locator (nisvcloc.exe) in versions prior to 18.0 on Windows. This may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate privileges. | ||||
CVE-2021-38304 | 1 Ni | 1 Ni-pal | 2024-11-21 | 7.8 High |
Improper input validation in the National Instruments NI-PAL driver in versions 20.0.0 and prior may allow a privileged user to potentially enable escalation of privilege via local access. |