Search Results (323539 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-10639 1 Eaton 2 Hmisoft Vu3, Hmisoft Vu3 Firmware 2024-11-21 7.8 High
Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could cause a buffer overflow when loaded by the affected product.
CVE-2020-10638 1 Advantech 1 Webaccess 2024-11-21 9.8 Critical
Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple heap-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution.
CVE-2020-10637 1 Eaton 2 Hmisoft Vu3, Hmisoft Vu3 Firmware 2024-11-21 5.5 Medium
Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could trigger an out-of-bounds read when loaded by the affected product.
CVE-2020-10634 1 Sae-it 2 Net-line Fw-50, Net-line Fw-50 Firmware 2024-11-21 9.1 Critical
SAE IT-systems FW-50 Remote Telemetry Unit (RTU). A specially crafted request could allow an attacker to view the file structure of the affected device and access files that should be inaccessible.
CVE-2020-10633 1 Hms-networks 4 Ewon Cosy, Ewon Cosy Firmware, Ewon Flexy and 1 more 2024-11-21 6.1 Medium
A non-persistent XSS (cross-site scripting) vulnerability exists in eWON Flexy and Cosy (all firmware versions prior to 14.1s0). An attacker could send a specially crafted URL to initiate a password change for the device. The target must introduce the credentials to the gateway before the attack can be successful.
CVE-2020-10631 1 Advantech 1 Webaccess\/nms 2024-11-21 9.8 Critical
An attacker could use a specially crafted URL to delete or read files outside the WebAccess/NMS's (versions prior to 3.0.2) control.
CVE-2020-10630 1 Sae-it 2 Net-line Fw-50, Net-line Fw-50 Firmware 2024-11-21 6.1 Medium
SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users.
CVE-2020-10629 1 Advantech 1 Webaccess\/nms 2024-11-21 7.5 High
WebAccess/NMS (versions prior to 3.0.2) does not sanitize XML input. Specially crafted XML input could allow an attacker to read sensitive files.
CVE-2020-10628 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2024-11-21 7.5 High
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network.
CVE-2020-10627 1 Insulet 2 Omnipod Insulin Management System, Omnipod Insulin Management System Firmware 2024-11-21 7.3 High
Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.
CVE-2020-10626 2 Fazecast, Schneider-electric 2 Jserialcomm, Ecostruxure It Gateway 2024-11-21 7.8 High
In Fazecast jSerialComm, Version 2.2.2 and prior, an uncontrolled search path element vulnerability could allow a malicious DLL file with the same name of any resident DLLs inside the software installation to execute arbitrary code.
CVE-2020-10625 1 Advantech 1 Webaccess\/nms 2024-11-21 9.8 Critical
WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.
CVE-2020-10624 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2024-11-21 7.5 High
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network.
CVE-2020-10623 1 Advantech 1 Webaccess\/nms 2024-11-21 6.5 Medium
Multiple vulnerabilities could allow an attacker with low privileges to perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.
CVE-2020-10622 1 Lcds 1 Laquis Scada 2024-11-21 7.8 High
LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users
CVE-2020-10621 1 Advantech 1 Webaccess\/nms 2024-11-21 9.8 Critical
Multiple issues exist that allow files to be uploaded and executed on the WebAccess/NMS (versions prior to 3.0.2).
CVE-2020-10620 1 Opto22 1 Softpac Project 2024-11-21 9.8 Critical
Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC communication does not include any credentials. This allows an attacker with network access to directly communicate with SoftPAC, including, for example, stopping the service remotely.
CVE-2020-10619 1 Advantech 1 Webaccess\/nms 2024-11-21 9.1 Critical
An attacker could use a specially crafted URL to delete files outside the WebAccess/NMS's (versions prior to 3.0.2) control.
CVE-2020-10618 1 Lcds 1 Laquis Scada 2024-11-21 5.5 Medium
LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.
CVE-2020-10617 1 Advantech 1 Webaccess\/nms 2024-11-21 7.5 High
There are multiple ways an unauthenticated attacker could perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.