| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In Moxa NPort 5210, 5230, and 5232 versions 2.9 build 17030709 and prior, the amount of resources requested by a malicious actor are not restricted, allowing for a denial-of-service condition. |
| For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is left open. |
| AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process. |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can use the SOAP API to retrieve and change sensitive configuration items such as the usernames and passwords for the Web and FTP servers. This vulnerability does not affect the i.LON 600 product. |
| In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information. |
| Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior performs read operations on a memory buffer where the position can be determined by a value read from a .dpa file. This may cause improper restriction of operations within the bounds of the memory buffer, allow remote code execution, alter the intended control flow, allow reading of sensitive information, or cause the application to crash. |
| Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length stack buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash. |
| AVEVA InduSoft Web Studio v8.1 and v8.1SP1, and InTouch Machine Edition v2017 8.1 and v2017 8.1 SP1 a remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. |
| An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation. |
| Davolink DVW-3200N all version prior to Version 1.00.06. The device generates a weak password hash that is easily cracked, allowing a remote attacker to obtain the password for the device. |
| Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length heap buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash. |
| ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used. |
| Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform. |
| An XXE vulnerability in LeviStudioU, Versions 1.8.29 and 1.8.44 can be exploited when the application processes specially crafted project XML files. |
| Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior. |
| In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. |
| Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services. |
| An out-of-bounds vulnerability in LeviStudioU, Versions 1.8.29 and 1.8.44 can be exploited when the application processes specially crafted project files. |
| Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow improper sanitization of data over a Websocket which may allow cross-site scripting and client-side code execution with target user privileges. |
| SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required. |