| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. |
| Rengine v1.3.0 was discovered to contain a command injection vulnerability via the scan engine function. |
| Incorrect access control in the install directory (C:\Wamp64) of Wamp v3.2.6 and below allows authenticated attackers to execute arbitrary code via overwriting binaries located in the directory. |
| Incorrect access control in the install directory (C:\Strawberry) of StrawberryPerl v5.32.1.1 and below allows authenticated attackers to execute arbitrary code via overwriting binaries located in the directory. |
| Incorrect access control in the install directory (C:\RailsInstaller) of Rubyinstaller2 v3.1.2 and below allows authenticated attackers to execute arbitrary code via overwriting binaries located in the directory. |
| Incorrect access control in the install directory (C:\Ruby31-x64) of Rubyinstaller2 v3.1.2 and below allows authenticated attackers to execute arbitrary code via overwriting binaries located in the directory. |
| XPDF v4.0.4 was discovered to contain a segmentation violation via the component /xpdf/AcroForm.cc:538. |
| Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh. |
| Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi. |
| Seiko SkyBridge MB-A100/A110 v4.2.0 and below implements a hard-coded passcode for the root account. Attackers are able to access the passcord via the file /etc/ciel.cfg. |
| Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain an arbitrary file upload vulnerability via the restore backup function. This vulnerability allows attackers to execute arbitrary code via a crafted html file. |
| Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain a command injection vulnerability via the ipAddress parameter at 07system08execute_ping_01. |
| Hytec Inter HWL-2511-SS v1.05 and below implements a SHA512crypt hash for the root account which can be easily cracked via a brute-force attack. |
| A command injection vulnerability in the CLI (Command Line Interface) implementation of Hytec Inter HWL-2511-SS v1.05 and below allows attackers to execute arbitrary commands with root privileges. |
| Hytec Inter HWL-2511-SS v1.05 and below was discovered to contain a command injection vulnerability via the component /www/cgi-bin/popen.cgi. |
| Tenda AC6(AC1200) v5.0 Firmware v02.03.01.114 and below contains an issue in the component /cgi-bin/DownloadFlash which allows attackers to steal all data such as source code and system files via a crafted GET request. |
| A Server Side Request Forgery (SSRF) in the Data Import module in Heartex - Label Studio Community Edition versions 1.5.0 and earlier allows an authenticated user to access arbitrary files on the system. Furthermore, self-registration is enabled by default in these versions of Label Studio enabling a remote attacker to create a new account and then exploit the SSRF. |
| WeDayCare B.V Ouderapp before v1.1.22 allows attackers to alter the ID value within intercepted calls to gain access to data of other parents and children. |
| An issue in the component post_applogin.php of Super Flexible Software GmbH & Co. KG Syncovery 9 for Linux v9.47x and below allows attackers to escalate privileges via creating crafted session tokens. |
| Super Flexible Software GmbH & Co. KG Syncovery 9 for Linux v9.47x and below was discovered to contain multiple remote code execution (RCE) vulnerabilities via the Job_ExecuteBefore and Job_ExecuteAfter parameters at post_profilesettings.php. |