| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Biscom Secure File Transfer (SFT) 5.0.1050 through 5.1.1067 and 6.0.1000 through 6.0.1003 allows Insecure Direct Object Reference (IDOR) by an authenticated sender because of an error in a file-upload feature. This is fixed in 5.1.1068 and 6.0.1004. |
| In Artica Pandora FMS 7.42, Web Admin users can execute arbitrary code by uploading a .php file via the Updater or Extension component. NOTE: The vendor reports that this is intended functionality |
| XSS exists in the shortcode functionality of the GistPress plugin before 3.0.2 for WordPress via the includes/class-gistpress.php id parameter. This allows an attacker with the WordPress Contributor role to execute arbitrary JavaScript code with the privileges of other users (e.g., ones who have the publish_posts capability). |
| In Artica Pandora FMS through 7.42, an unauthenticated attacker can read the chat history. The file is in JSON format and it contains user names, user IDs, private messages, and timestamps. |
| In Kronos Web Time and Attendance (webTA) 4.1.x and later 4.x versions before 5.0, there is a Stored XSS vulnerability by setting the Application Banner input field of the /ApplicationBanner page as an authenticated administrator. |
| In Kronos Web Time and Attendance (webTA) 3.8.x and later 3.x versions before 4.0, the com.threeis.webta.H491delegate servlet allows an attacker with Timekeeper or Supervisor privileges to gain unauthorized administrative privileges within the application via the delegate, delegateRole, and delegatorUserId parameters. |
| In Kronos Web Time and Attendance (webTA) 3.8.x and later 3.x versions before 4.0, the com.threeis.webta.H402editUser servlet allows an attacker with Timekeeper, Master Timekeeper, or HR Admin privileges to gain unauthorized administrative privileges within the application via the emp_id, userid, pw1, pw2, supervisor, and timekeeper parameters. |
| A stored XSS vulnerability in Kronos Web Time and Attendance (webTA) affects 3.8.x and later 3.x versions before 4.0 via multiple input fields (Login Message, Banner Message, and Password Instructions) of the com.threeis.webta.H261configMenu servlet via an authenticated administrator. |
| Python 2.7 through 2.7.17, 3.5 through 3.5.9, 3.6 through 3.6.10, 3.7 through 3.7.6, and 3.8 through 3.8.1 allows an HTTP server to conduct Regular Expression Denial of Service (ReDoS) attacks against a client because of urllib.request.AbstractBasicAuthHandler catastrophic backtracking. |
| Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable. |
| Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities. |
| Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. |
| Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. |
| Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. |
| Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. |
| Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data |
| For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer. |
| For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling. |
| Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder. |
| The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code. |