Filtered by vendor Abb
Subscriptions
Total
126 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-6298 | 1 Abb | 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more | 2024-11-21 | 9.8 Critical |
Improper Input Validation vulnerability in ABB ASPECT-Enterprise on Linux, ABB NEXUS Series on Linux, ABB MATRIX Series on Linux allows Remote Code Inclusion.This issue affects ASPECT-Enterprise: through 3.08.01; NEXUS Series: through 3.08.01; MATRIX Series: through 3.08.01. | ||||
CVE-2024-6209 | 1 Abb | 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more | 2024-11-21 | 7.5 High |
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v <=3.08.01; NEXUS Series v <=3.08.01 ; MATRIX Series v<=3.08.01 allows Attacker to access files unauthorized | ||||
CVE-2024-5402 | 1 Abb | 1 Mint Workbench | 2024-11-21 | 7.8 High |
Unquoted Search Path or Element vulnerability in ABB Mint Workbench. A local attacker who successfully exploited this vulnerability could gain elevated privileges by inserting an executable file in the path of the affected service. This issue affects Mint Workbench I versions: from 5866 before 5868. | ||||
CVE-2024-4009 | 1 Abb | 10 2tma310010b0001, 2tma310010b0001 Firmware, 2tma310010b0003 and 7 more | 2024-11-21 | 9.2 Critical |
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System | ||||
CVE-2024-4008 | 1 Abb | 10 2tma310010b0001, 2tma310010b0001 Firmware, 2tma310010b0003 and 7 more | 2024-11-21 | 9.6 Critical |
FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System | ||||
CVE-2024-0335 | 1 Abb | 3 Symphony Plus S\+ Analyst, Symphony Plus S\+ Engineering, Symphony Plus S\+ Operations | 2024-11-21 | 7.5 High |
ABB has internally identified a vulnerability in the ABB VPNI feature of the S+ Control API component which may be used by several Symphony Plus products (e.g., S+ Operations, S+ Engineering and S+ Analyst) This issue affects Symphony Plus S+ Operations: from 3..0;0 through 3.3 SP1 RU4, from 2.1;0 through 2.1 SP2 RU3, from 2.0;0 through 2.0 SP6 TC6; Symphony Plus S+ Engineering: from 2.1 through 2.3 RU3; Symphony Plus S+ Analyst: from 7.0.0.0 through 7.2.0.2. | ||||
CVE-2023-3324 | 1 Abb | 1 Zenon | 2024-11-21 | 6.3 Medium |
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | ||||
CVE-2023-3323 | 1 Abb | 1 Zenon | 2024-11-21 | 5.9 Medium |
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | ||||
CVE-2023-3322 | 1 Abb | 1 Zenon | 2024-11-21 | 7 High |
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | ||||
CVE-2023-3321 | 1 Abb | 1 Zenon | 2024-11-21 | 7 High |
A vulnerability exists by allowing low-privileged users to read and update the data in various directories used by the Zenon system. An attacker could exploit the vulnerability by using specially crafted programs to exploit the vulnerabilities by allowing them to run on the zenon installed hosts. This issue affects ABB Ability™ zenon: from 11 build through 11 build 106404. | ||||
CVE-2023-2876 | 1 Abb | 6 Rex640 Pcl1, Rex640 Pcl1 Firmware, Rex640 Pcl2 and 3 more | 2024-11-21 | 3.1 Low |
Sensitive Cookie Without 'HttpOnly' Flag vulnerability in ABB REX640 PCL1 (firmware modules), ABB REX640 PCL2 (Firmware modules), ABB REX640 PCL3 (firmware modules) allows Cross-Site Scripting (XSS).This issue affects REX640 PCL1: from 1.0;0 before 1.0.8; REX640 PCL2: from 1.0;0 before 1.1.4; REX640 PCL3: from 1.0;0 before 1.2.1. | ||||
CVE-2023-2685 | 1 Abb | 1 Ao-opc | 2024-11-21 | 7.2 High |
A vulnerability was found in AO-OPC server versions mentioned above. As the directory information for the service entry is not enclosed in quotation marks, potential attackers could possibly call up another application than the AO-OPC server by starting the service. The service might be started with system user privileges which could cause a shift in user access privileges. It is unlikely to exploit the vulnerability in well maintained Windows installations since the attacker would need write access to system folders. An update is available that resolves the vulnerability found during an internal review in the product AO-OPC = 3.2.1 | ||||
CVE-2023-2625 | 1 Abb | 2 Txpert Hub Coretec 4, Txpert Hub Coretec 4 Firmware | 2024-11-21 | 9 Critical |
A vulnerability exists that can be exploited by an authenticated client that is connected to the same network segment as the CoreTec 4, having any level of access VIEWER to ADMIN. To exploit the vulnerability the attacker can inject shell commands through a particular field of the web user interface that will be executed by the system. | ||||
CVE-2023-1258 | 1 Abb | 16 Flow-x\/c, Flow-x\/c Firmware, Flow-x\/k and 13 more | 2024-11-21 | 5.3 Medium |
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in ABB Flow-X firmware on Flow-X embedded hardware (web service modules) allows Footprinting.This issue affects Flow-X: before 4.0. | ||||
CVE-2023-0864 | 1 Abb | 16 Terra Ac Wallbox 80a, Terra Ac Wallbox 80a Firmware, Terra Ac Wallbox Ce Juno and 13 more | 2024-11-21 | 7.1 High |
Cleartext Transmission of Sensitive Information vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5. | ||||
CVE-2023-0863 | 1 Abb | 16 Terra Ac Wallbox 80a, Terra Ac Wallbox 80a Firmware, Terra Ac Wallbox Ce Juno and 13 more | 2024-11-21 | 8.8 High |
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5. | ||||
CVE-2023-0636 | 1 Abb | 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more | 2024-11-21 | 7.2 High |
Improper Input Validation vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Command Injection.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.0; NEXUS Series: from 3.0;0 before 3.07.0; MATRIX Series: from 3.0;0 before 3.07.1. | ||||
CVE-2023-0635 | 1 Abb | 38 Aspect-ent-12, Aspect-ent-12 Firmware, Aspect-ent-2 and 35 more | 2024-11-21 | 7.8 High |
Improper Privilege Management vulnerability in ABB Ltd. ASPECT®-Enterprise on ASPECT®-Enterprise, Linux (2CQG103201S3021, 2CQG103202S3021, 2CQG103203S3021, 2CQG103204S3021 modules), ABB Ltd. NEXUS Series on NEXUS Series, Linux (2CQG100102R2021, 2CQG100104R2021, 2CQG100105R2021, 2CQG100106R2021, 2CQG100110R2021, 2CQG100112R2021, 2CQG100103R2021, 2CQG100107R2021, 2CQG100108R2021, 2CQG100109R2021, 2CQG100111R2021, 2CQG100113R2021 modules), ABB Ltd. MATRIX Series on MATRIX Series, Linux (2CQG100102R1021, 2CQG100103R1021, 2CQG100104R1021, 2CQG100105R1021, 2CQG100106R1021 modules) allows Privilege Escalation.This issue affects ASPECT®-Enterprise: from 3.0;0 before 3.07.01; NEXUS Series: from 3.0;0 before 3.07.01; MATRIX Series: from 3.0;0 before 3.07.01. | ||||
CVE-2023-0580 | 1 Abb | 1 My Control System | 2024-11-21 | 5.4 Medium |
Insecure Storage of Sensitive Information vulnerability in ABB My Control System (on-premise) allows an attacker who successfully exploited this vulnerability to gain access to the secure application data or take control of the application. Of the services that make up the My Control System (on-premise) application, the following ones are affected by this vulnerability: User Interface System Monitoring1 Asset Inventory This issue affects My Control System (on-premise): from 5.0;0 through 5.13. | ||||
CVE-2023-0426 | 1 Abb | 8 Ac700f, Ac700f Firmware, Ac900f and 5 more | 2024-11-21 | 8.6 High |
ABB is aware of vulnerabilities in the product versions listed below. An update is available that resolves the reported vulnerabilities in the product versions under maintenance. An attacker who successfully exploited one or more of these vulnerabilities could cause the product to stop or make the product inaccessible. Stack-based Buffer Overflow vulnerability in ABB Freelance controllers AC 700F (conroller modules), ABB Freelance controllers AC 900F (controller modules).This issue affects: Freelance controllers AC 700F: from 9.0;0 through V9.2 SP2, through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019 , through Freelance 2019 SP1, through Freelance 2019 SP1 FP1; Freelance controllers AC 900F: through Freelance 2013, through Freelance 2013SP1, through Freelance 2016, through Freelance 2016SP1, through Freelance 2019, through Freelance 2019 SP1, through Freelance 2019 SP1 FP1. |