Search vulnerabilities

Results 34,816

CVE-2023-22807

CVE-2023-22807

LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-0104

The listed versions for Weintek EasyBuilder Pro are vulnerable to a ZipSlip attack caused by decompiling a malicious project file. This may allow an attacker to gain control of the user’s computer or gain access to sensitive data.  

CVSS 3.1 · 9.3 Critical EPSS 21.8% KEV · Not listed
Vendors
Products
CVE-2023-0352

CVE-2023-0352

The Akuvox E11 password recovery webpage can be accessed without authentication, and an attacker could download the device key file. An attacker could then use this page to reset the password back to the default.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-0354

CVE-2023-0354

The Akuvox E11 web server can be accessed without any user authentication, and this could allow an attacker to access sensitive information, as well as create and download packet captures with known default URLs.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-0345

CVE-2023-0345

The Akuvox E11 secure shell (SSH) server is enabled by default and can be accessed by the root user. This password cannot be changed by the user.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-0811

Omron CJ1M unit v4.0 and prior has improper access controls on the memory region where the UM password is stored. If an adversary issues a PROGRAM AREA WRITE command to a specific memory region, they could overwrite the password. This may lead to disabling UM protections or setting a non-ASCII password (non-keyboard characters) and preventing an engineer from viewing or modifying the user program.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-1256

CVE-2023-1256

The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-1136

CVE-2023-1136

In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-1140

CVE-2023-1140

Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
Vendors
CVE-2023-28654

CVE-2023-28654

Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-27394

CVE-2023-27394

Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts.

CVSS 3.1 · 9.8 Critical EPSS 17.6% KEV · Not listed
Vendors
CVE-2023-28398

CVE-2023-28398

Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller.

CVSS 3.1 · 9.8 Critical EPSS < 1% KEV · Not listed
Vendors
CVE-2023-0344

CVE-2023-0344

Akuvox E11 appears to be using a custom version of dropbear SSH server. This server allows an insecure option that by default is not in the official dropbear SSH server.

CVSS 3.1 · 9.1 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-1748

CVE-2023-1748

The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server (MQTT) server and the ability to remotely control garage doors or smart plugs for any customer.

CVSS 3.1 · 9.3 Critical EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2023-2131

CVE-2023-2131

Versions of INEA ME RTU firmware prior to 3.36 are vulnerable to OS command injection, which could allow an attacker to remotely execute arbitrary code.

CVSS 3.1 · 10 Critical EPSS 1.7% KEV · Not listed
Vendors
CVE-2023-1968

CVE-2023-1968

Instruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications.

CVSS 3.1 · 10 Critical EPSS 1.8% KEV · Not listed
Vendors
Products
CVE-2023-2586

Teltonika’s Remote Management System versions 4.14.0 is vulnerable to an unauthorized attacker registering previously unregistered devices through the RMS platform. If the user has not disabled the "RMS management feature" enabled by default, then an attacker could register that device to themselves. This could enable the attacker to perform different operations on the user's devices, including remote code execution with 'root' privileges (using the 'Task Manager' feature on RMS).

CVSS 3.1 · 9 Critical EPSS 1.0% KEV · Not listed
Vendors