Filtered by vendor Ls-electric Subscriptions
Total 8 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-22807 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2024-11-21 9.8 Critical
LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.
CVE-2023-22806 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2024-11-21 7.5 High
LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information such as user credentials.
CVE-2023-22805 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2024-11-21 6.5 Medium
LS ELECTRIC XBC-DN32U with operating system version 01.80 has improper access control to its read prohibition feature. This could allow a remote attacker to remotely set the feature to lock users out of reading data from the device.
CVE-2023-22804 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2024-11-21 9.1 Critical
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
CVE-2023-22803 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2024-11-21 7.5 High
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
CVE-2023-0103 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2024-11-21 7.5 High
If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.
CVE-2023-0102 1 Ls-electric 2 Xbc-dn32u, Xbc-dn32u Firmware 2024-11-21 9.1 Critical
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.
CVE-2022-2758 1 Ls-electric 469 Gm7, Gm7 Firmware, Gm7u and 466 more 2024-11-21 6.5 Medium
Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic.