Search Results (85232 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2018-25218 2 Krylack, Passfab 2 Rar Password Recovery, Rar Password Recovery 2026-03-31 8.4 High
PassFab RAR Password Recovery 9.3.2 contains a structured exception handler (SEH) buffer overflow vulnerability that allows local attackers to execute arbitrary code by supplying a malicious payload. Attackers can craft a payload with a buffer overflow, NSEH jump, and shellcode, then paste it into the 'Licensed E-mail and Registration Code' field during registration to trigger code execution.
CVE-2026-28297 1 Solarwinds 1 Observability Self-hosted 2026-03-31 6.1 Medium
SolarWinds Observability Self-Hosted was found to be affected by a stored cross-site scripting vulnerability, which when exploited, can lead to unintended script execution.
CVE-2026-28298 1 Solarwinds 1 Observability Self-hosted 2026-03-31 5.9 Medium
SolarWinds Observability Self-Hosted was found to be affected by a stored cross-site scripting vulnerability, which when exploited, can lead to unintended script execution.
CVE-2026-26073 2 Everest, Linuxfoundation 2 Everest-core, Everest 2026-03-31 5.9 Medium
EVerest is an EV charging software stack. Versions prior to 2026.02.0 have a data race leading to possible `std::queue`/`std::deque` corruption. The trigger is powermeter public key update and EV session/error events (while OCPP not started). This results in a TSAN data race report and an ASAN/UBSAN misaligned address runtime error being observed. Version 2026.02.0 contains a patch.
CVE-2026-27815 2 Everest, Linuxfoundation 2 Everest-core, Everest 2026-03-31 9.1 Critical
EVerest is an EV charging software stack. Prior to versions to 2026.02.0, ISO15118_chargerImpl::handle_session_setup copies a variable-length payment_options list into a fixed-size array of length 2 without bounds checking. With schema validation disabled by default, oversized MQTT Cmd payloads can trigger out-of-bounds writes and corrupt adjacent EVSE state or crash the process. Version 2026.02.0 contains a patch.
CVE-2026-27816 2 Everest, Linuxfoundation 2 Everest-core, Everest 2026-03-31 9.1 Critical
EVerest is an EV charging software stack. Prior to versions to 2026.02.0, ISO15118_chargerImpl::handle_update_energy_transfer_modes copies a variable-length list into a fixed-size array of length 6 without bounds checking. With schema validation disabled by default, oversized MQTT Cmd payloads can trigger out-of-bounds writes and corrupt adjacent EVSE state or crash the process. Version 2026.02.0 contains a patch.
CVE-2026-33402 2 Sakailms, Sakaiproject 2 Sakai, Sakai 2026-03-31 6.1 Medium
Sakai is a Collaboration and Learning Environment (CLE). In versions 23.0 through 23.4 and 25.0 through 25.1, group titles and description can contain cross-site scripting scripts. The patch is included in releases 25.2 and 23.5. As a workaround, one can check the SAKAI_SITE_GROUP table for titles and descriptions that contain this info.
CVE-2026-33623 1 Pinchtab 1 Pinchtab 2026-03-31 6.7 Medium
PinchTab is a standalone HTTP server that gives AI agents direct control over a Chrome browser. PinchTab `v0.8.4` contains a Windows-only command injection issue in the orphaned Chrome cleanup path. When an instance is stopped, the Windows cleanup routine builds a PowerShell `-Command` string using a `needle` derived from the profile path. In `v0.8.4`, that string interpolation escapes backslashes but does not safely neutralize other PowerShell metacharacters. If an attacker can launch an instance using a crafted profile name and then trigger the cleanup path, they may be able to execute arbitrary PowerShell commands on the Windows host in the security context of the PinchTab process user. This is not an unauthenticated internet RCE. It requires authenticated, administrative-equivalent API access to instance lifecycle endpoints, and the resulting command execution inherits the permissions of the PinchTab OS user rather than bypassing host privilege boundaries. Version 0.8.5 contains a patch for the issue.
CVE-2026-33664 2 Kestra, Kestra-io 2 Kestra, Kestra 2026-03-31 7.3 High
Kestra is an open-source, event-driven orchestration platform Versions up to and including 1.3.3 render user-supplied flow YAML metadata fields — description, inputs[].displayName, inputs[].description — through the Markdown.vue component instantiated with html: true. The resulting HTML is injected into the DOM via Vue's v-html without any sanitization. This allows a flow author to embed arbitrary JavaScript that executes in the browser of any user who views or interacts with the flow. This is distinct from GHSA-r36c-83hm-pc8j / CVE-2026-29082, which covers only FilePreview.vue rendering .md files from execution outputs. The present finding affects different components, different data sources, and requires significantly less user interaction (zero-click for input.displayName). As of time of publication, it is unclear if a patch is available.
CVE-2026-4902 1 Tenda 2 Ac5, Ac5 Firmware 2026-03-31 8.8 High
A vulnerability was detected in Tenda AC5 15.03.06.47. This affects the function fromAddressNat of the file /goform/addressNat of the component POST Request Handler. The manipulation of the argument page results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used.
CVE-2026-33743 2 Linuxcontainers, Lxc 2 Incus, Incus 2026-03-31 6.5 Medium
Incus is a system container and virtual machine manager. Prior to version 6.23.0, a specially crafted storage bucket backup can be used by an user with access to Incus' storage bucket feature to crash the Incus daemon. Repeated use of this attack can be used to keep the server offline causing a denial of service of the control plane API. This does not impact any running workload, existing containers and virtual machines will keep operating. Version 6.23.0 fixes the issue.
CVE-2026-4961 1 Tenda 2 Ac6, Ac6 Firmware 2026-03-31 8.8 High
A vulnerability was identified in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formQuickIndex of the file /goform/QuickIndex of the component POST Request Handler. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used.
CVE-2026-33871 1 Netty 1 Netty 2026-03-31 7.5 High
Netty is an asynchronous, event-driven network application framework. In versions prior to 4.1.132.Final and 4.2.10.Final, a remote user can trigger a Denial of Service (DoS) against a Netty HTTP/2 server by sending a flood of `CONTINUATION` frames. The server's lack of a limit on the number of `CONTINUATION` frames, combined with a bypass of existing size-based mitigations using zero-byte frames, allows an user to cause excessive CPU consumption with minimal bandwidth, rendering the server unresponsive. Versions 4.1.132.Final and 4.2.10.Final fix the issue.
CVE-2026-33916 1 Handlebarsjs 1 Handlebars 2026-03-31 4.7 Medium
Handlebars provides the power necessary to let users build semantic templates. In versions 4.0.0 through 4.7.8, `resolvePartial()` in the Handlebars runtime resolves partial names via a plain property lookup on `options.partials` without guarding against prototype-chain traversal. When `Object.prototype` has been polluted with a string value whose key matches a partial reference in a template, the polluted string is used as the partial body and rendered without HTML escaping, resulting in reflected or stored XSS. Version 4.7.9 fixes the issue. Some workarounds are available. Apply `Object.freeze(Object.prototype)` early in application startup to prevent prototype pollution. Note: this may break other libraries, and/or use the Handlebars runtime-only build (`handlebars/runtime`), which does not compile templates and reduces the attack surface.
CVE-2026-33939 1 Handlebarsjs 1 Handlebars 2026-03-31 7.5 High
Handlebars provides the power necessary to let users build semantic templates. In versions 4.0.0 through 4.7.8, when a Handlebars template contains decorator syntax referencing an unregistered decorator (e.g. `{{*n}}`), the compiled template calls `lookupProperty(decorators, "n")`, which returns `undefined`. The runtime then immediately invokes the result as a function, causing an unhandled `TypeError: ... is not a function` that crashes the Node.js process. Any application that compiles user-supplied templates without wrapping the call in a `try/catch` is vulnerable to a single-request Denial of Service. Version 4.7.9 fixes the issue. Some workarounds are available. Wrap compilation and rendering in `try/catch`. Validate template input before passing it to `compile()`; reject templates containing decorator syntax (`{{*...}}`) if decorators are not used in your application. Use the pre-compilation workflow; compile templates at build time and serve only pre-compiled templates; do not call `compile()` at request time.
CVE-2026-5024 2 D-link, Dlink 3 Dir-513, Dir-513, Dir-513 Firmware 2026-03-31 8.8 High
A vulnerability was found in D-Link DIR-513 1.10. This issue affects the function formSetEmail of the file /goform/formSetEmail. Performing a manipulation of the argument curTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2026-5043 1 Belkin 2 F9k1122, F9k1122 Firmware 2026-03-31 8.8 High
A weakness has been identified in Belkin F9K1122 1.00.33. The impacted element is the function formSetPassword of the file /goform/formSetPassword of the component Parameter Handler. This manipulation of the argument webpage causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-32980 1 Openclaw 1 Openclaw 2026-03-31 7.5 High
OpenClaw before 2026.3.13 reads and buffers Telegram webhook request bodies before validating the x-telegram-bot-api-secret-token header, allowing unauthenticated attackers to exhaust server resources. Attackers can send POST requests to the webhook endpoint to force memory consumption, socket time, and JSON parsing work before authentication validation occurs.
CVE-2026-4974 1 Tenda 2 Ac7, Ac7 Firmware 2026-03-31 8.8 High
A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
CVE-2025-47901 1 Microchip 2 Timeprovider 4100, Timeprovider 4100 Firmware 2026-03-31 8.8 High
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Microchip Time Provider 4100 allows OS Command Injection.This issue affects Time Provider 4100: before 2.5.