Search Results (328456 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-7005 1 Honeywell 1 Win-pak 2024-11-21 8.8 High
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable to a cross-site request forgery, which may allow an attacker to remotely execute arbitrary code.
CVE-2020-7004 1 Visam 2 Vbase Editor, Vbase Web-remote 2024-11-21 8.8 High
VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow weak or insecure permissions on the VBASE directory resulting in elevation of privileges or malicious effects on the system the next time a privileged user runs the application.
CVE-2020-7003 1 Moxa 40 Iologik 2512, Iologik 2512-hspa, Iologik 2512-hspa-t and 37 more 2024-11-21 7.5 High
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is transmitted over some web applications in clear text.
CVE-2020-7002 1 Deltaww 1 Cncsoft Screeneditor 2024-11-21 7.8 High
Delta Industrial Automation CNCSoft ScreenEditor, v1.00.96 and prior. Multiple stack-based buffer overflows can be exploited when a valid user opens a specially crafted, malicious input file.
CVE-2020-7001 1 Moxa 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more 2024-11-21 7.5 High
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
CVE-2020-7000 1 Visam 2 Vbase Editor, Vbase Web-remote 2024-11-21 7.5 High
VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow an unauthenticated attacker to discover the cryptographic key from the web server and gain information about the login and the encryption/decryption mechanism, which may be exploited to bypass authentication of the HTML5 HMI web interface.
CVE-2020-6999 1 Moxa 2 Mds-g516e, Mds-g516e Firmware 2024-11-21 6.5 Medium
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, some of the parameters in the setting pages do not ensure text is the correct size for its buffer.
CVE-2020-6997 1 Moxa 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more 2024-11-21 7.5 High
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext.
CVE-2020-6996 1 Trianglemicroworks 1 Dnp3 Source Code Library 2024-11-21 9.8 Critical
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
CVE-2020-6995 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2024-11-21 9.8 Critical
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access.
CVE-2020-6994 1 Belden 14 Hirschmann Eagle20, Hirschmann Eagle30, Hirschmann Embedded Ethernet Switch and 11 more 2024-11-21 9.8 Critical
A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.
CVE-2020-6993 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2024-11-21 7.5 High
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization.
CVE-2020-6992 1 Ge 1 Cimplicity 2024-11-21 6.7 Medium
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
CVE-2020-6991 1 Moxa 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more 2024-11-21 9.8 Critical
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force.
CVE-2020-6990 1 Rockwellautomation 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more 2024-11-21 9.8 Critical
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.
CVE-2020-6989 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2024-11-21 9.8 Critical
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.
CVE-2020-6988 1 Rockwellautomation 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more 2024-11-21 7.5 High
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
CVE-2020-6987 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2024-11-21 7.5 High
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
CVE-2020-6986 1 Omron 4 Plc Cj1, Plc Cj1 Firmware, Plc Cj2 and 1 more 2024-11-21 7.5 High
In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service error on the PLC Ethernet module, which in turn causes a PLC service denied result.
CVE-2020-6985 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2024-11-21 9.8 Critical
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.