| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In OpenMRS 2.9 and prior, the export functionality of the Data Exchange Module does not properly redirect to a login page when an unauthenticated user attempts to access it. This allows the export of potentially sensitive information. |
| In OpenMRS 2.9 and prior, he import functionality of the Data Exchange Module does not properly redirect to a login page when an unauthenticated user attempts to access it. This allows unauthenticated users to use a feature typically restricted to administrators. |
| In OpenMRS 2.9 and prior, the app parameter for the ActiveVisit's page is vulnerable to cross-site scripting. |
| In OpenMRS 2.9 and prior, the sessionLocation parameter for the login page is vulnerable to cross-site scripting. |
| In OpenMRS 2.9 and prior, the UI Framework Error Page reflects arbitrary, user-supplied input back to the browser, which can result in XSS. Any page that is able to trigger a UI Framework Error is susceptible to this issue. |
| OpenMRS 2.9 and prior copies "Referrer" header values into an html element named "redirectUrl" within many webpages (such as login.htm). There is insufficient validation for this parameter, which allows for the possibility of cross-site scripting. |
| Authentication bypass using an alternate path or channel in SimpliSafe SS3 firmware 1.4 allows a local, unauthenticated attacker to pair a rogue keypad to an armed system. |
| The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the CTI server on port 8888. A remote unauthenticated attacker can invoke the challenge action with a crafted username and discover user passwords. |
| The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the HTTP server's websockify endpoint. A remote unauthenticated attacker can invoke the login action with a crafted username and, through the use of timing attacks, can discover user passwords. |
| The Grandstream UCM6200 series before 1.0.20.22 is vulnerable to an SQL injection via the HTTP server's websockify endpoint. A remote unauthenticated attacker can invoke the challenge action with a crafted username and discover user passwords. |
| The UCM6200 series 1.0.20.22 and below stores unencrypted user passwords in an SQLite database. This could allow an attacker to retrieve all passwords and possibly gain elevated privileges. |
| MikroTik WinBox 3.22 and below stores the user's cleartext password in the settings.cfg.viw configuration file when the Keep Password field is set and no Master Password is set. Keep Password is set by default and, by default Master Password is not set. An attacker with access to the configuration file can extract a username and password to gain access to the router. |
| MikroTik WinBox before 3.21 is vulnerable to a path traversal vulnerability that allows creation of arbitrary files wherevere WinBox has write permissions. WinBox is vulnerable to this attack if it connects to a malicious endpoint or if an attacker mounts a man in the middle attack. |
| Incorrect implementation of authentication algorithm issue in UNIVERGE SV9500 series from V1 to V7and SV8500 series from S6 to S8 allows an attacker to access the remote system maintenance feature and obtain the information by sending a specially crafted request to a specific URL. |
| UNIVERGE SV9500 series from V1 to V7and SV8500 series from S6 to S8 allows an attacker to execute arbitrary OS commands or cause a denial-of-service (DoS) condition by sending a specially crafted request to a specific URL. |
| iSM client versions from V5.1 prior to V12.1 running on NEC Storage Manager or NEC Storage Manager Express does not verify a server certificate properly, which allows a man-in-the-middle attacker to eavesdrop on an encrypted communication or alter the communication via a crafted certificate. |
| Directory traversal vulnerability in GROWI versions prior to v4.2.3 (v4.2 Series), GROWI versions prior to v4.1.12 (v4.1 Series), and GROWI v3 series and earlier GROWI versions prior to v4.2.3 (v4.2 Series), GROWI versions prior to v4.1.12 (v4.1 Series), and GROWI v3 series and earlier allows remote attackers to alter the data by uploading a specially crafted file. |
| Improper input validation in GROWI versions prior to v4.2.3 (v4.2 Series), GROWI versions prior to v4.1.12 (v4.1 Series), and GROWI v3 series and earlier GROWI versions prior to v4.2.3 (v4.2 Series), GROWI versions prior to v4.1.12 (v4.1 Series), and GROWI v3 series and earlier allows remote attackers to cause a denial of service via unspecified vectors. |
| Untrusted search path vulnerability in self-extracting files created by EpsonNet SetupManager versions 2.2.14 and earlier, and Offirio SynergyWare PrintDirector versions 1.6x/1.6y and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Improper input validation vulnerability in EC-CUBE versions from 3.0.5 to 3.0.18 allows a remote attacker to cause a denial-of-service (DoS) condition via unspecified vector. |