Search Results (322821 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-10658 1 Proofpoint 1 Insider Threat Management Server 2024-11-21 9.8 Critical
The Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.9.1 contains a vulnerability in the ITM application server's WriteImage API. The vulnerability allows an anonymous remote attacker to execute arbitrary code with local administrator privileges. The vulnerability is caused by improper deserialization.
CVE-2020-10657 1 Proofpoint 1 Insider Threat Management Server 2024-11-21 7.2 High
The Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.9.1 contains a vulnerability in the ITM web console's ImportAlertRules feature. The vulnerability allows a remote attacker (with admin or config-admin privileges in the console) to execute arbitrary code with local administrator privileges. The vulnerability is caused by improper deserialization.
CVE-2020-10656 1 Proofpoint 1 Insider Threat Management Server 2024-11-21 9.8 Critical
The Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.9.1 contains a vulnerability in the ITM application server's WriteWindowMouseWithChunksV2 API. The vulnerability allows an anonymous remote attacker to execute arbitrary code with local administrator privileges. The vulnerability is caused by improper deserialization.
CVE-2020-10655 1 Proofpoint 1 Insider Threat Management Server 2024-11-21 9.8 Critical
The Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.9.1 contains a vulnerability in the ITM application server's WriteWindowMouse API. The vulnerability allows an anonymous remote attacker to execute arbitrary code with local administrator privileges. The vulnerability is caused by improper deserialization.
CVE-2020-10654 1 Pingidentity 1 Pingid Ssh Integration 2024-11-21 9.8 Critical
Ping Identity PingID SSH before 4.0.14 contains a heap buffer overflow in PingID-enrolled servers. This condition can be potentially exploited into a Remote Code Execution vector on the authenticating endpoint.
CVE-2020-10649 2 Asus, Microsoft 2 Device Activation, Windows 10 2024-11-21 7.8 High
DevActSvc.exe in ASUS Device Activation before 1.0.7.0 for Windows 10 notebooks and PCs could lead to unsigned code execution with no additional restrictions when a user puts an application at a particular path with a particular file name.
CVE-2020-10648 2 Denx, Opensuse 2 U-boot, Leap 2024-11-21 7.8 High
Das U-Boot through 2020.01 allows attackers to bypass verified boot restrictions and subsequently boot arbitrary images by providing a crafted FIT image to a system configured to boot the default configuration.
CVE-2020-10646 1 Fujielectric 1 V-server 2024-11-21 7.8 High
Fuji Electric V-Server Lite all versions prior to 4.0.9.0 contains a heap based buffer overflow. The buffer allocated to read data, when parsing VPR files, is too small.
CVE-2020-10644 1 Inductiveautomation 1 Ignition Gateway 2024-11-21 7.5 High
The affected product lacks proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.
CVE-2020-10643 1 Osisoft 1 Pi Vision 2024-11-21 6.5 Medium
An authenticated remote attacker could use specially crafted URLs to send a victim using PI Vision 2019 mobile to a vulnerable web page due to a known issue in a third-party component.
CVE-2020-10642 1 Rockwellautomation 1 Rslinx Classic 2024-11-21 7.8 High
In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.
CVE-2020-10641 1 Inductiveautomation 1 Ignition Gateway 2024-11-21 7.5 High
An unprotected logging route may allow an attacker to write endless log statements into the database without space limits or authentication. This results in consuming the entire available hard-disk space on the Ignition 8 Gateway (versions prior to 8.0.10), causing a denial-of-service condition.
CVE-2020-10639 1 Eaton 2 Hmisoft Vu3, Hmisoft Vu3 Firmware 2024-11-21 7.8 High
Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could cause a buffer overflow when loaded by the affected product.
CVE-2020-10638 1 Advantech 1 Webaccess 2024-11-21 9.8 Critical
Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple heap-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution.
CVE-2020-10637 1 Eaton 2 Hmisoft Vu3, Hmisoft Vu3 Firmware 2024-11-21 5.5 Medium
Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could trigger an out-of-bounds read when loaded by the affected product.
CVE-2020-10634 1 Sae-it 2 Net-line Fw-50, Net-line Fw-50 Firmware 2024-11-21 9.1 Critical
SAE IT-systems FW-50 Remote Telemetry Unit (RTU). A specially crafted request could allow an attacker to view the file structure of the affected device and access files that should be inaccessible.
CVE-2020-10633 1 Hms-networks 4 Ewon Cosy, Ewon Cosy Firmware, Ewon Flexy and 1 more 2024-11-21 6.1 Medium
A non-persistent XSS (cross-site scripting) vulnerability exists in eWON Flexy and Cosy (all firmware versions prior to 14.1s0). An attacker could send a specially crafted URL to initiate a password change for the device. The target must introduce the credentials to the gateway before the attack can be successful.
CVE-2020-10631 1 Advantech 1 Webaccess\/nms 2024-11-21 9.8 Critical
An attacker could use a specially crafted URL to delete or read files outside the WebAccess/NMS's (versions prior to 3.0.2) control.
CVE-2020-10630 1 Sae-it 2 Net-line Fw-50, Net-line Fw-50 Firmware 2024-11-21 6.1 Medium
SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users.
CVE-2020-10629 1 Advantech 1 Webaccess\/nms 2024-11-21 7.5 High
WebAccess/NMS (versions prior to 3.0.2) does not sanitize XML input. Specially crafted XML input could allow an attacker to read sensitive files.