| In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product. |
| In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. |
| In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage this vulnerability to delete files while posing as an administrator. |
| Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that causes the program to mishandle pointers. |
| In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information. |
| Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap. |
| In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials. |
| A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). |
| SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password. |
| Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that operates outside of the designated memory area. |
| In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition. |
| Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files. |
| An out-of-bounds read vulnerability has been identified in Fuji Electric Alpha7 PC Loader Versions 1.1 and prior, which may crash the system. |
| NREL EnergyPlus, Versions 8.6.0 and possibly prior versions, The application fails to prevent an exception handler from being overwritten with arbitrary code. |
| Quest KACE, all versions prior to version 8.0.x, 8.1.x, and 9.0.x, allows unintentional access to the appliance leveraging functions of the troubleshooting tools located in the administrator user interface. |
| Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted. |
| The application (Network Configurator for DeviceNet Safety 3.41 and prior) searches for resources by means of an untrusted search path that could execute a malicious .dll file not under the application's direct control and outside the intended directories. |
| In Rockwell Automation PanelView 5510 (all versions manufactured before March 13, 2019 that have never been updated to v4.003, v5.002, or later), a remote, unauthenticated threat actor with access to an affected PanelView 5510 Graphic Display, upon successful exploit, may boot-up the terminal and gain root-level access to the device’s file system. |
| Moxa EDR 810, all versions 5.1 and prior, allows an authenticated attacker to abuse the ping feature to execute unauthorized commands on the router, which may allow an attacker to perform remote code execution. |
| Philips Holter 2010 Plus, all versions. A vulnerability has been identified that may allow system options that were not purchased to be enabled. |