D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualApp. This vulnerability is triggered via a crafted POST request.
Search vulnerabilities
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80046eb4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Unauthenticated API Endpoints.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. An Undocumented Backdoor exists, allowing shell access via a developer account.
The HTTP client in MashZone NextGen through 10.7 GA deserializes untrusted data when it gets an HTTP response with a 570 status code.
In the pg_partman (aka PG Partition Manager) extension before 4.5.1 for PostgreSQL, arbitrary code execution can be achieved via SECURITY DEFINER functions because an explicit search_path is not set.
In Expression Engine before 6.0.3, addonIcon in Addons/file/mod.file.php relies on the untrusted input value of input->get('file') instead of the fixed file names of icon.png and icon.svg.
MiNiFi CPP arbitrary script execution is possible on the agent's host machine through the c2 protocol
From Apache NiFi MiNiFi C++ version 0.5.0 the c2 protocol implements an "agent-update" command which was designed to patch the application binary. This "patching" command defaults to calling a trusted binary, but might be modified to an arbitrary value through a "c2-update" command. Said command is then executed using the same privileges as the application binary. This was addressed in version 0.10.0
Zoho ManageEngine ADSelfService Plus through 6102 allows unauthenticated remote code execution in non-English editions.
Some Dahua products have access control vulnerability in the password reset process. Attackers can exploit this vulnerability through specific deployments to reset device passwords.
A Remote Code Execution (RCE) vulnerability in the WebUI component of the eQ-3 HomeMatic CCU2 firmware up to and including version 2.57.5 and CCU3 firmware up to and including version 3.57.5 allows remote unauthenticated attackers to execute system commands as root via a simple HTTP request.
Sylabs Singularity Enterprise through 1.6.2 has Insufficient Entropy in a nonce.
The Flask-Caching extension through 1.10.1 for Flask relies on Pickle for serialization, which may lead to remote code execution or local privilege escalation. If an attacker gains access to cache storage (e.g., filesystem, Memcached, Redis, etc.), they can construct a crafted payload, poison the cache, and execute Python code. NOTE: a third party indicates that exploitation is extremely unlikely unless the machine is already compromised; in other cases, the attacker would be unable to write their payload to the cache and generate the required collision
Advantech WebAccess
Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code.
FATEK Automation WinProladder Versions 3.30 and prior do not properly restrict operations within the bounds of a memory buffer, which may allow an attacker to execute arbitrary code.
FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
FATEK Automation WinProladder Versions 3.30 and prior are vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code.
A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.