A remote unauthenticated arbitrary code execution vulnerability was discovered in Aruba Airwave Software version(s): Prior to 1.3.2.
Search vulnerabilities
A remote unauthenticated arbitrary code execution vulnerability was discovered in Aruba Airwave Software version(s): Prior to 1.3.2.
A remote unauthorized access vulnerability was discovered in Aruba Airwave Software version(s): Prior to 1.3.2.
The ClearPass Policy Manager web interface is affected by a vulnerability that leads to authentication bypass. Upon successful bypass an attacker could then execute an exploit that would allow to remote command execution in the underlying operating system. Resolution: Fixed in 6.7.13-HF, 6.8.5-HF, 6.8.6, 6.9.1 and higher.
A vulnerability exists allowing attackers, when present in the same network segment as ClearPass' management interface, to make changes to certain databases in ClearPass by crafting HTTP packets. As a result of this attack, a possible complete cluster compromise might occur. Resolution: Fixed in 6.7.13, 6.8.4, 6.9.0 and higher.
The Elementor Page Builder plugin before 2.8.4 for WordPress does not sanitize data during creation of a new template.
An issue was discovered in Elementor 2.7.4. Arbitrary file upload is possible in the Elementor Import Templates function, allowing an attacker to execute code via a crafted ZIP archive.
The WordPress plugin, WP Database Reset through 3.1, contains a flaw that allowed any unauthenticated user to reset any table in the database to the initial WordPress set-up state (deleting all site content stored in that table), as demonstrated by a wp-admin/admin-post.php?db-reset-tables[]=comments URI.
An issue was discovered in openfortivpn 1.11.0 when used with OpenSSL before 1.0.2. tunnel.c mishandles certificate validation because hostname comparisons do not consider '\0' characters, as demonstrated by a good.example.com\x00evil.example.com attack.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the attacker may execute arbitrary codes or target the device, causing it to go out of service.
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access.
A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
In Notifier Web Server (NWS) Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser.
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server.