It is possible to unmask credentials and other sensitive information on “unprotected” project files, which may allow an attacker to remotely access the C-More Touch Panels EA9 series: firmware versions prior to 6.53 and manipulate system configurations.
Search vulnerabilities
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch contain an SQL injection vulnerability that could give an attacker remote unauthenticated access to the web user interface with administrator-level privileges.
The following versions of MAXPRO VMS and NVR, MAXPRO VMS:HNMSWVMS prior to Version VMS560 Build 595 T2-Patch, HNMSWVMSLT prior to Version VMS560 Build 595 T2-Patch, MAXPRO NVR: MAXPRO NVR XE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR SE prior to Version NVR 5.6 Build 595 T2-Patch, MAXPRO NVR PE prior to Version NVR 5.6 Build 595 T2-Patch, and MPNVRSWXX prior to Version NVR 5.6 Build 595 T2-Patch are vulnerable to an unsafe deserialization of untrusted data. An attacker may be able to remotely modify deserialized data without authentication using a specially crafted web request, resulting in remote code execution.
An XXE vulnerability in JnlpSupport in Yet Another Java Service Wrapper (YAJSW) 12.14, as used in NSA Ghidra and other products, allows attackers to exfiltrate data from remote hosts and potentially cause denial-of-service.
A remote code execution issue was discovered in HashBrown CMS through 1.3.3. Server/Entity/Deployer/GitDeployer.js has a Service.AppService.exec call that mishandles the URL, repository, username, and password.
Tableau Server installations configured with Site-Specific SAML that allows the APIs to be used by unauthenticated users. If exploited, this could allow a malicious user to configure Site-Specific SAML settings and could lead to account takeover for users of that site. Tableau Server versions affected on both Windows and Linux are: 2018.2 through 2018.2.27, 2018.3 through 2018.3.24, 2019.1 through 2019.1.22, 2019.2 through 2019.2.18, 2019.3 through 2019.3.14, 2019.4 through 2019.4.13, 2020.1 through 2020.1.10, 2020.2 through 2020.2.7, and 2020.3 through 2020.3.2.
A ZXELINK wireless controller has a SQL injection vulnerability. A remote attacker does not need to log in. By sending malicious SQL statements, because the device does not properly filter parameters, successful use can obtain management rights. This affects: ZXV10 W908 all versions before MIPS_A_1022IPV6R3T6P7Y20.
A ZTE product is impacted by the improper access control vulnerability. Due to lack of an authentication protection mechanism in the program, attackers could use this vulnerability to gain access right through brute-force attacks. This affects: <ZXONE 19700 SNPE><ZXONE8700V1.40R2B13_SNPE>
A ZTE product is impacted by the cryptographic issues vulnerability. The encryption algorithm is not properly used, so remote attackers could use this vulnerability for account credential enumeration attack or brute-force attack for password guessing. This affects: ZXIPTV, ZXIPTV-WEB-PV5.09.08.04.
The server management software module of ZTE has an authentication issue vulnerability, which allows users to skip the authentication of the server and execute some commands for high-level users. This affects: <R5300G4V03.08.0100/V03.07.0300/V03.07.0200/V03.07.0108/V03.07.0100/V03.05.0047/V03.05.0046/V03.05.0045/V03.05.0044/V03.05.0043/V03.05.0040/V03.04.0020;R8500G4V03.07.0103/V03.07.0101/V03.06.0100/V03.05.0400/V03.05.0020;R5500G4V03.08.0100/V03.07.0200/V03.07.0100/V03.06.0100>
CACAGOO Cloud Storage Intelligent Camera TV-288ZD-2MP with firmware 3.4.2.0919 has weak authentication of TELNET access, leading to root privileges without any password required.
D-Link DCH-M225 1.05b01 and earlier devices allow remote attackers to execute arbitrary OS commands via shell metacharacters in the spotifyConnect.php userName parameter.
In mruby 2.1.0, there is a use-after-free in hash_slice in mrbgems/mruby-hash-ext/src/hash-ext.c.
In mruby 2.1.0, there is a stack-based buffer overflow in mrb_str_len_to_dbl in string.c.