| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A security flaw has been discovered in Tenda AC15 15.03.05.18. Affected is an unknown function of the file /goform/saveAutoQos. Performing manipulation of the argument enable results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been released to the public and may be exploited. |
| Secure Boot Security Feature Bypass Vulnerability |
| Secure Boot Security Feature Bypass Vulnerability |
| Secure Boot Security Feature Bypass Vulnerability |
| Secure Boot Security Feature Bypass Vulnerability |
| SQL Server Native Client OLE DB Provider Remote Code Execution Vulnerability |
| Secure Boot Security Feature Bypass Vulnerability |
| Secure Boot Security Feature Bypass Vulnerability |
| Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.3.0.15, LTS2025 release version 8.3.1.0, LTS2024 release versions 7.13.1.0 through 7.13.1.30, LTS 2023 release versions 7.10.1.0 through 7.10.1.60, contain a Stack-based Buffer Overflow vulnerability in the DDSH CLI. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Denial of service. |
| Dell PowerProtect Data Domain with Data Domain Operating System (DD OS) of Feature Release versions 7.7.1.0 through 8.3.0.15, LTS2025 release version 8.3.1.0, LTS2024 release versions 7.13.1.0 through 7.13.1.30, LTS 2023 release versions 7.10.1.0 through 7.10.1.60, contain a Stack-based Buffer Overflow vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Denial of service. |
| iptraf-ng 1.2.1 has a stack-based buffer overflow. In src/ifaces.c, the strcpy function consistently fails to control the size, and it is consequently possible to overflow memory on the stack. |
| A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. |
| A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used. |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions), User Management Component (UMC) (All versions < V2.15.1.3). Affected products contain a stack-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code or to cause a denial of service condition. |
| A vulnerability has been found in MicroWord eScan Antivirus 7.0.32 on Linux and classified as critical. Affected by this vulnerability is the function passPrompt of the component USB Protection Service. The manipulation leads to stack-based buffer overflow. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A stack-based buffer overflow can be remotely triggered when formatting an error message in the Control-M/Agent when SSL/TLS communication is configured.
The issue occurs in the following cases:
* Control-M/Agent 9.0.20: SSL/TLS configuration is set to the non-default setting "use_openssl=n";
* Control-M/Agent 9.0.21 and 9.0.22: Agent router configuration uses the non-default settings "JAVA_AR=N" and "use_openssl=n". |
| A buffer overflow in the Control-M/Agent can lead to a local privilege escalation when an attacker has access to the system running the Agent.
This vulnerability impacts the out-of-support Control-M/Agent versions 9.0.18 to 9.0.20 and potentially earlier unsupported versions. |
| A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. |
| A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used. |
| A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. |