Search Results (4312 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-0884 1 Microsoft 2 Visual Studio 2017, Visual Studio 2019 2024-11-21 3.7 Low
A spoofing vulnerability exists in Microsoft Visual Studio as it includes a reply URL that is not secured by SSL, aka 'Microsoft Visual Studio Spoofing Vulnerability'.
CVE-2019-9873 1 Jetbrains 1 Intellij Idea 2024-11-21 N/A
In several versions of JetBrains IntelliJ IDEA Ultimate, creating Task Servers configurations leads to saving a cleartext unencrypted record of the server credentials in the IDE configuration files. The issue has been fixed in the following versions: 2019.1, 2018.3.5, 2018.2.8, and 2018.1.8.
CVE-2019-9872 1 Jetbrains 1 Intellij Idea 2024-11-21 N/A
In several versions of JetBrains IntelliJ IDEA Ultimate, creating run configurations for cloud application servers leads to saving a cleartext unencrypted record of the server credentials in the IDE configuration files. If the Settings Repository plugin was then used and configured to synchronize IDE settings using a public repository, these credentials were published to this repository. The issue has been fixed in the following versions: 2019.1, 2018.3.5, 2018.2.8, and 2018.1.8.
CVE-2019-9862 1 Abus 6 Secvest Wireless Alarm System Fuaa50000, Secvest Wireless Alarm System Fuaa50000 Firmware, Secvest Wireless Remote Control Fube50014 and 3 more 2024-11-21 N/A
An issue was discovered on ABUS Secvest wireless alarm system FUAA50000 3.01.01 in conjunction with Secvest remote control FUBE50014 or FUBE50015. Because "encrypted signal transmission" is missing, an attacker is able to eavesdrop sensitive data as cleartext (for instance, the current rolling code state).
CVE-2019-9861 1 Abus 2 Secvest Wireless Alarm System Fuaa50000, Secvest Wireless Alarm System Fuaa50000 Firmware 2024-11-21 N/A
Due to the use of an insecure RFID technology (MIFARE Classic), ABUS proximity chip keys (RFID tokens) of the ABUS Secvest FUAA50000 wireless alarm system can easily be cloned and used to deactivate the alarm system in an unauthorized way.
CVE-2019-9860 1 Abus 6 Secvest Wireless Alarm System Fuaa50000, Secvest Wireless Alarm System Fuaa50000 Firmware, Secvest Wireless Remote Control Fube50014 and 3 more 2024-11-21 N/A
Due to unencrypted signal communication and predictability of rolling codes, an attacker can "desynchronize" an ABUS Secvest wireless remote control (FUBE50014 or FUBE50015) relative to its controlled Secvest wireless alarm system FUAA50000 3.01.01, so that sent commands by the remote control are not accepted anymore.
CVE-2019-9823 1 Jetbrains 1 Intellij Idea 2024-11-21 N/A
In several JetBrains IntelliJ IDEA versions, creating remote run configurations of JavaEE application servers leads to saving a cleartext record of the server credentials in the IDE configuration files. The issue has been fixed in the following versions: 2018.3.5, 2018.2.8, 2018.1.8.
CVE-2019-9681 1 Dahuasecurity 18 Ipc-hdbw4x2x, Ipc-hdbw4x2x Firmware, Ipc-hdw1x2x and 15 more 2024-11-21 5.3 Medium
Online upgrade information in some firmware packages of Dahua products is not encrypted. Attackers can obtain this information by analyzing firmware packages by specific means. Affected products include: IPC-HDW1X2X,IPC-HFW1X2X,IPC-HDW2X2X,IPC-HFW2X2X,IPC-HDW4X2X,IPC-HFW4X2X,IPC-HDBW4X2X,IPC-HDW5X2X,IPC-HFW5X2X for versions which Build time is before August 18,2019.
CVE-2019-9532 1 Cobham 2 Explorer 710, Explorer 710 Firmware 2024-11-21 7.8 High
The web application portal of the Cobham EXPLORER 710, firmware version 1.07, sends the login password in cleartext. This could allow an unauthenticated, local attacker to intercept the password and gain access to the portal.
CVE-2019-9506 8 Apple, Blackberry, Canonical and 5 more 280 Iphone Os, Mac Os X, Tvos and 277 more 2024-11-21 8.1 High
The Bluetooth BR/EDR specification up to and including version 5.1 permits sufficiently low encryption key length and does not prevent an attacker from influencing the key length negotiation. This allows practical brute-force attacks (aka "KNOB") that can decrypt traffic and inject arbitrary ciphertext without the victim noticing.
CVE-2019-9191 1 Etsi 1 Enterprise Transport Security 2024-11-21 N/A
The ETSI Enterprise Transport Security (ETS, formerly known as eTLS) protocol does not provide per-session forward secrecy.
CVE-2019-9104 1 Moxa 12 Mb3170, Mb3170 Firmware, Mb3180 and 9 more 2024-11-21 7.5 High
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. The application's configuration file contains parameters that represent passwords in cleartext.
CVE-2019-9101 1 Moxa 12 Mb3170, Mb3170 Firmware, Mb3180 and 9 more 2024-11-21 7.5 High
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server.
CVE-2019-8632 1 Apple 1 Texture 2024-11-21 6.5 Medium
Some analytics data was sent using HTTP rather than HTTPS. This was addressed by no longer sending this analytics data. This issue is fixed in Texture 5.11.10 for iOS, Texture 4.22.0.4 for Android. An attacker in a privileged network position may be able to intercept analytics data.
CVE-2019-8345 1 Estrongs 1 Es File Explorer File Manager 2024-11-21 N/A
The Help feature in the ES File Explorer File Manager application 4.1.9.7.4 for Android allows session hijacking by a Man-in-the-middle attacker on the local network because HTTPS is not used, and an attacker's web site is displayed in a WebView with no information about the URL.
CVE-2019-8118 1 Magento 1 Magento 2024-11-21 5.3 Medium
Magento 2.1 prior to 2.1.19, Magento 2.2 prior to 2.2.10, Magento 2.3 prior to 2.3.3 uses weak cryptographic function to store the failed login attempts for customer accounts.
CVE-2019-7675 1 Mobotix 2 S14, S14 Firmware 2024-11-21 N/A
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. The default management application is delivered over cleartext HTTP with Basic Authentication, as demonstrated by the /admin/index.html URI.
CVE-2019-7311 1 Linksys 2 Wrt1900acs, Wrt1900acs Firmware 2024-11-21 N/A
An issue was discovered on Linksys WRT1900ACS 1.0.3.187766 devices. A lack of encryption in how the user login cookie (admin-auth) is stored on a victim's computer results in the admin password being discoverable by a local attacker, and usable to gain administrative access to the victim's router. The admin password is stored in base64 cleartext in an "admin-auth" cookie. An attacker sniffing the network at the time of login could acquire the router's admin password. Alternatively, gaining physical access to the victim's computer soon after an administrative login could result in compromise.
CVE-2019-6846 1 Schneider-electric 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more 2024-11-21 6.5 Medium
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
CVE-2019-6845 1 Schneider-electric 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more 2024-11-21 7.5 High
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol.