Search vulnerabilities

Results 425,467

CVE-2020-10644

The affected product lacks proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.

CVSS 3.1 · 7.5 High EPSS 20.2% KEV · Not listed
Products
CVE-2020-10643

OSIsoft PI System

An authenticated remote attacker could use specially crafted URLs to send a victim using PI Vision 2019 mobile to a vulnerable web page due to a known issue in a third-party component.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10642

In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Products
CVE-2020-10641

An unprotected logging route may allow an attacker to write endless log statements into the database without space limits or authentication. This results in consuming the entire available hard-disk space on the Ignition 8 Gateway (versions prior to 8.0.10), causing a denial-of-service condition.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed
Products
CVE-2020-10639

Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could cause a buffer overflow when loaded by the affected product.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10638

Advantech WebAccess Node, Version 8.4.4 and prior, Version 9.0.0. Multiple heap-based buffer overflow vulnerabilities exist caused by a lack of proper validation of the length of user-supplied data, which may allow remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 7.1% KEV · Not listed
Vendors
Products
CVE-2020-10637

Eaton HMiSoft VU3 (HMIVU3 runtime not impacted), Version 3.00.23 and prior, however, the HMIVU runtimes are not impacted by these issues. A specially crafted input file could trigger an out-of-bounds read when loaded by the affected product.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10634

SAE IT-systems FW-50 Remote Telemetry Unit (RTU). A specially crafted request could allow an attacker to view the file structure of the affected device and access files that should be inaccessible.

CVSS 3.1 · 9.1 Critical EPSS 1.4% KEV · Not listed
Vendors
CVE-2020-10633

A non-persistent XSS (cross-site scripting) vulnerability exists in eWON Flexy and Cosy (all firmware versions prior to 14.1s0). An attacker could send a specially crafted URL to initiate a password change for the device. The target must introduce the credentials to the gateway before the attack can be successful.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10631

An attacker could use a specially crafted URL to delete or read files outside the WebAccess/NMS's (versions prior to 3.0.2) control.

CVSS 3.1 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2020-10630

SAE IT-systems FW-50 Remote Telemetry Unit (RTU). The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in the output used as a webpage that is served to other users.

CVSS 3.1 · 6.1 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10629

WebAccess/NMS (versions prior to 3.0.2) does not sanitize XML input. Specially crafted XML input could allow an attacker to read sensitive files.

CVSS 3.1 · 7.5 High EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2020-10627

Insulet Omnipod Insulin Management System insulin pump product ID 19191 and 40160 is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

CVSS 3.1 · 7.3 High EPSS < 1% KEV · Not listed
Vendors
CVE-2020-10625

WebAccess/NMS (versions prior to 3.0.2) allows an unauthenticated remote user to create a new admin account.

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2020-10623

Multiple vulnerabilities could allow an attacker with low privileges to perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access to sensitive information.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10622

LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to arbitrary file creation by unauthorized users

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2020-10621

Multiple issues exist that allow files to be uploaded and executed on the WebAccess/NMS (versions prior to 3.0.2).

CVSS 3.1 · 9.8 Critical EPSS 1.6% KEV · Not listed
Vendors
Products