| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| RevelaCode is an AI-powered faith-tech project that decodes biblical verses, prophecies and global events into accessible language. In versions below 1.0.1, a valid MongoDB Atlas URI with embedded username and password was accidentally committed to the public repository. This could allow unauthorized access to production or staging databases, potentially leading to data exfiltration, modification, or deletion. This is fixed in version 1.0.1. Workarounds include: immediately rotating credentials for the exposed database user, using a secret manager (like Vault, Doppler, AWS Secrets Manager, etc.) instead of storing secrets directly in code, or auditing recent access logs for suspicious activity. |
| Dependency-Track is a component analysis platform that allows organizations to identify and reduce risk in the software supply chain. Prior to version 4.13.5, Dependency-Track may send credentials meant for a private NuGet repository to `api.nuget.org` via the HTTP `Authorization` header, and may disclose names and versions of components marked as internal to `api.nuget.org`. This can happen if the Dependency-Track instance contains .NET components, a custom NuGet repository has been configured, the custom repository has been configured with authentication credentials, and the repository server does not provide `PackageBaseAddress` resource in its service index. The issue has been fixed in Dependency-Track 4.13.5. Some workarounds are avaialble. Disable custom NuGet repositories until the patch has been applied, invalidate the previously used credentials, and generate new credentials for usage after the patch has been applied. |
| Due to information disclosure vulnerability in anonymous API provided by SAP Business One (SLD), an attacker with normal user access could gain access to unauthorized information. As a result, it has a low impact on the confidentiality of the application but no impact on the integrity and availability. |
| General Industrial Controls Lynx+ Gateway is vulnerable to a weak password requirement vulnerability, which may
allow an attacker to execute a brute-force attack resulting in
unauthorized access and login. |
| Access to TSplus Remote Access Admin Tool is restricted to administrators (unless "Disable UAC" option is enabled) and requires a PIN code. In versions below v18.40.6.17 the PIN's hash is stored in a system registry accessible to regular users, making it possible to perform a brute-force attack using rainbow tables, since the hash is not salted.
LTS (Long-Term Support) versions also received patches in v17.2025.6.27 and v16.2025.6.27 releases. |
| The user management section of the web application permits the creation of user accounts with excessively weak passwords, including single-character passwords. |
| Utilizing default credentials, an attacker is able to log into the camera's operating system which could allow changes to be made to the operations or shutdown the camera requiring a physical reboot of the system. |
| apko is an apk-based OCI image builder. apko exposures HTTP basic auth credentials from repository and keyring URLs in log output. This vulnerability is fixed in v0.14.5. |
| MTPutty 1.0.1.21 contains a sensitive information disclosure vulnerability that allows local attackers to view SSH connection passwords through Windows PowerShell process listing. Attackers can run a PowerShell command to retrieve the full command line of MTPutty processes, exposing plaintext SSH credentials. |
| In Puppet Enterprise versions 2025.4.0 and 2025.5, the encryption key used for encrypting content in the Infra Assistant database was not excluded from the files gathered by Puppet backup. The key is only present on the system if the user has a Puppet Enterprise Advanced license and has enabled the Infra Assistant feature. The key is used for encrypting one particular bit of data in the Infra Assistant database: the API key for their AI provider account. This has been fixed in Puppet Enterprise version 2025.6, and release notes for 2025.6 have remediation steps for users of affected versions who can't update to the latest version. |
| Insufficiently protected credentials issue exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent unauthenticated attacker may obtain sensitive information such as a username and its password in the address book. |
| A flaw was found in org.keycloak/keycloak-model-storage-service. The KeycloakRealmImport custom resource substitutes placeholders within imported realm documents, potentially referencing environment variables. This substitution process
allows for injection attacks when crafted realm documents are processed. An attacker can leverage this to inject malicious content during the realm import procedure. This can lead to unintended consequences within the Keycloak environment. |
| Mobile Scanner Android App version 2.12.38 (package name com.glority.everlens), developed by Glority Global Group Ltd., contains a credential leakage vulnerability. Improper handling of cloud service credentials may allow attackers to obtain them and carry out unauthorized actions, such as sensitive information disclosure and abuse of cloud resources. Successful exploitation could result in privacy breaches and misuse of the platform infrastructure. |
| An authenticated attacker can reconfigure the target device to use an external service (such as LDAP or FTP) controlled by the attacker. If an existing password is present for an external service, the attacker can force the target device to authenticate to an attacker controlled device using the existing credentials for that external service. In the case of an external LDAP or FTP service, this will disclose the plaintext password for that external service to the attacker. |
| HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection. |
| HGW BL1500HM Ver 002.001.013 and earlier contains a use of week credentials issue. A network-adjacent unauthenticated attacker may change the system settings. |
| Insufficiently protected credentials in GE HealthCare EchoPAC products |
| The webserver utilizes basic authentication for its user login to the configuration interface. As encryption is disabled on port 80, it enables potential eavesdropping on user traffic, making it possible to intercept their credentials. |
| Password Vulnerability in Safety production process management system v1.0 allows a remote attacker to escalate privileges, execute arbitrary code and obtain sensitive information via the password and account number parameters. |
| Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior. |