Search Results (4312 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-18800 1 Rakuten 1 Viber 2024-11-21 8.8 High
Viber through 11.7.0.5 allows a remote attacker who can capture a victim's internet traffic to steal their Viber account, because not all Viber protocol traffic is encrypted. TCP data packet 9 on port 4244 from the victim's device contains cleartext information such as the device model and OS version, IMSI, and 20 bytes of udid in a binary format, which is located at offset 0x14 of this packet. Then, the attacker installs Viber on his device, initiates the registration process for any phone number, but doesn't enter a pin from SMS. Instead, he closes Viber. Next, the attacker rewrites his udid with the victim's udid, modifying the viber_udid file, which is located in the Viber preferences folder. (The udid is stored in a hexadecimal format.) Finally, the attacker starts Viber again and enters the pin from SMS.
CVE-2019-18630 1 Xerox 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more 2024-11-21 7.5 High
On Xerox AltaLink B8045/B8055/B8065/B8075/B8090 and C8030/C8035/C8045/C8055/C8070 multifunction printers with software releases before 101.00x.099.28200, portions of the drive containing executable code were not encrypted thus leaving it open to potential cryptographic information disclosure.
CVE-2019-18615 1 Arista 1 Cloudvision Portal 2024-11-21 4.9 Medium
In CloudVision Portal (CVP) for all releases in the 2018.2 Train, under certain conditions, the application logs user passwords in plain text for certain API calls, potentially leading to user password exposure. This only affects CVP environments where: 1. Devices have enable mode passwords which are different from the user's login password, OR 2. There are configlet builders that use the Device class and specify username and password explicitly Application logs are not accessible or visible from the CVP GUI. Application logs can only be read by authorized users with privileged access to the VM hosting the CVP application.
CVE-2019-18285 1 Siemens 1 Sppa-t3000 Application Server 2024-11-21 5.9 Medium
A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). The RMI communication between the client and the Application Server is unencrypted. An attacker with access to the communication channel can read credentials of a valid user. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-18254 1 Biotronik 4 Cardiomessenger Ii-s Gsm, Cardiomessenger Ii-s Gsm Firmware, Cardiomessenger Ii-s T-line and 1 more 2024-11-21 4.6 Medium
BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest. An attacker with physical access to the CardioMessenger can disclose medical measurement data and the serial number from the implanted cardiac device the CardioMessenger is paired with.
CVE-2019-18248 1 Biotronik 4 Cardiomessenger Ii-s Gsm, Cardiomessenger Ii-s Gsm Firmware, Cardiomessenger Ii-s T-line and 1 more 2024-11-21 4.3 Medium
BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure.
CVE-2019-18238 1 Moxa 40 Iologik 2512, Iologik 2512-hspa, Iologik 2512-hspa-t and 37 more 2024-11-21 7.5 High
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account.
CVE-2019-18231 1 Advantech 2 Spectre Rt Ert351, Spectre Rt Ert351 Firmware 2024-11-21 7.5 High
Advantech Spectre RT ERT351 Versions 5.1.3 and prior logins and passwords are transmitted in clear text form, which may allow an attacker to intercept the request.
CVE-2019-18201 1 Fujitsu 2 Lx390, Lx390 Firmware 2024-11-21 7.5 High
An issue was discovered on Fujitsu Wireless Keyboard Set LX390 GK381 devices. Because of the lack of proper encryption of 2.4 GHz communication, an attacker is able to eavesdrop on sensitive data such as passwords.
CVE-2019-18199 1 Fujitsu 2 Lx390, Lx390 Firmware 2024-11-21 6.6 Medium
An issue was discovered on Fujitsu Wireless Keyboard Set LX390 GK381 devices. Because of the lack of proper encryption of 2.4 GHz communication, and because of password-based authentication, they are vulnerable to replay attacks.
CVE-2019-17655 1 Fortinet 1 Fortios 2024-11-21 5.3 Medium
A cleartext storage in a file or on disk (CWE-313) vulnerability in FortiOS SSL VPN 6.2.0 through 6.2.2, 6.0.9 and earlier and FortiProxy 2.0.0, 1.2.9 and earlier may allow an attacker to retrieve a logged-in SSL VPN user's credentials should that attacker be able to read the session file stored on the targeted device's system.
CVE-2019-17393 1 Tomedo 1 Server 2024-11-21 9.8 Critical
The Customer's Tomedo Server in Version 1.7.3 communicates to the Vendor Tomedo Server via HTTP (in cleartext) that can be sniffed by unauthorized actors. Basic authentication is used for the authentication, making it possible to base64 decode the sniffed credentials and discover the username and password.
CVE-2019-17356 1 Infinitestudio 1 Infinite Design 2024-11-21 6.5 Medium
The Infinite Design application 3.4.12 for Android sends a username and password via TCP without any encryption during login, as demonstrated by sniffing of a public Wi-Fi network.
CVE-2019-17218 1 Vzug 2 Combi-stream Mslq, Combi-stream Mslq Firmware 2024-11-21 9.1 Critical
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. By default, the communication to the web service is unencrypted via http. An attacker is able to intercept and sniff communication to the web service.
CVE-2019-17106 1 Centreon 1 Centreon Web 2024-11-21 6.5 Medium
In Centreon Web through 2.8.29, disclosure of external components' passwords allows authenticated attackers to move laterally to external components.
CVE-2019-16924 1 Nuvending 1 Nulock 2024-11-21 8.8 High
The Nulock application 1.5.0 for mobile devices sends a cleartext password over Bluetooth, which allows remote attackers (after sniffing the network) to take control of the lock.
CVE-2019-16732 2 Petwant, Skymee 4 Pf-103, Pf-103 Firmware, Petalk Ai and 1 more 2024-11-21 8.1 High
Unencrypted HTTP communications for firmware upgrades in Petalk AI and PF-103 allow man-in-the-middle attackers to run arbitrary code as the root user.
CVE-2019-16672 1 Weidmueller 80 Ie-sw-pl08m-6tx-2sc, Ie-sw-pl08m-6tx-2sc Firmware, Ie-sw-pl08m-6tx-2scs and 77 more 2024-11-21 9.8 Critical
An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext.
CVE-2019-16568 1 Jenkins 1 Sctmexecutor 2024-11-21 5.3 Medium
Jenkins SCTMExecutor Plugin 2.2 and earlier transmits previously configured service credentials in plain text as part of the global configuration, as well as individual jobs' configurations.
CVE-2019-16545 1 Qmetry 1 Jenkins Qmetry For Jira 2024-11-21 6.5 Medium
Jenkins QMetry for JIRA - Test Management Plugin transmits credentials in its configuration in plain text as part of job configuration forms, potentially resulting in their exposure.