Search vulnerabilities

Results 427,646

CVE-2019-13553

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.

CVSS 3.1 · 9.8 Critical EPSS 2.3% KEV · Not listed
Vendors
CVE-2019-13552

In WebAccess versions 8.4.1 and prior, multiple command injection vulnerabilities are caused by a lack of proper validation of user-supplied data and may allow arbitrary file deletion and remote code execution.

CVSS 3.1 · 8.8 High EPSS 2.7% KEV · Not listed
Vendors
Products
CVE-2019-13551

Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. Path traversal vulnerabilities are caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage these vulnerabilities to remotely execute code while posing as an administrator.

CVSS 3.1 · 9.8 Critical EPSS 4.9% KEV · Not listed
Vendors
Products
CVE-2019-13550

In WebAccess, versions 8.4.1 and prior, an improper authorization vulnerability may allow an attacker to disclose sensitive information, cause improper control of generation of code, which may allow remote code execution or cause a system crash.

CVSS 3.1 · 9.8 Critical EPSS 2.8% KEV · Not listed
Vendors
Products
CVE-2019-13549

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.

CVSS 3.1 · 7.5 High EPSS 1.0% KEV · Not listed
Vendors
CVE-2019-13547

Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.

CVSS 3.1 · 9.8 Critical EPSS 3.3% KEV · Not listed
Vendors
Products
CVE-2019-13546

In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the application and access unauthorized resources from the Windows operating system as the limited-access Windows user. Due to potential Windows vulnerabilities, it may be possible for additional attack methods to be used to escalate privileges on the operating system.

CVSS 3.1 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2019-13545

In Horner Automation Cscape 9.90 and prior, improper validation of data may cause the system to write outside the intended buffer area, which may allow arbitrary code execution.

CVSS 3.1 · 7.8 High EPSS 1.9% KEV · Not listed
Products
CVE-2019-13544

Delta Electronics TPEditor, Versions 1.94 and prior. Multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files, which may allow remote code execution.

CVSS 3.1 · 7.8 High EPSS 1.9% KEV · Not listed
Vendors
Products
CVE-2019-13541

In Horner Automation Cscape 9.90 and prior, an improper input validation vulnerability has been identified that may be exploited by processing files lacking user input validation. This may allow an attacker to access information and remotely execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS 1.9% KEV · Not listed
Products
CVE-2019-13540

Delta Electronics TPEditor, Versions 1.94 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS 1.4% KEV · Not listed
Vendors
Products
CVE-2019-13538

3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only.

CVSS 3.1 · 8.6 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2019-13537

The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.

CVSS 3.1 · 7.5 High EPSS 1.3% KEV · Not listed
Vendors
CVE-2019-13536

Delta Electronics TPEditor, Versions 1.94 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS 1.4% KEV · Not listed
Vendors
Products
CVE-2019-13534

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.

CVSS 3.1 · 7.2 High EPSS < 1% KEV · Not listed
Vendors
Products
865240 865241 865242 and 16 more
CVE-2019-13530

Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware.

CVSS 3.1 · 7.2 High EPSS 1.4% KEV · Not listed
Vendors
Products
865240 865241 865242 and 16 more
CVE-2019-13528

A specific utility may allow an attacker to gain read access to privileged files in the Niagara AX 3.8u4 (JACE 3e, JACE 6e, JACE 7, JACE-8000), Niagara 4.4u3 (JACE 3e, JACE 6e, JACE 7, JACE-8000), and Niagara 4.7u1 (JACE-8000, Edge 10).

CVSS 3.1 · 4.4 Medium EPSS < 1% KEV · Not listed
Vendors
Products