CVE-2018-19027

Three type confusion vulnerabilities exist in CX-One Versions 4.50 and prior and CX-Protocol Versions 2.0 and prior when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.

CVSS 3.0 · 7.8 High EPSS 1.4% KEV · Not listed
Vendors
Products
CVE-2018-19025

In JUUKO K-808, an attacker could specially craft a packet that encodes an arbitrary command, which could be executed on the K-808 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.).

CVSS 3.1 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
CVE-2018-19023

Hetronic Nova-M prior to verson r161 uses fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state.

CVSS 3.0 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-19021

A specially crafted script could bypass the authentication of a maintenance port of Emerson DeltaV DCS Versions 11.3.1, 11.3.2, 12.3.1, 13.3.1, 14.3, R5.1, R6 and prior, which may allow an attacker to cause a denial of service.

CVSS 3.1 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-19020

When CX-Supervisor (Versions 3.42 and prior) processes project files and tampers with the value of an offset, an attacker can force the application to read a value outside of an array.

CVSS 3.0 · 5.0 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-19019

A type confusion vulnerability exists when processing project files in CX-Supervisor (Versions 3.42 and prior). An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.

CVSS 3.0 · 7.3 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2018-19018

An access of uninitialized pointer vulnerability in CX-Supervisor (Versions 3.42 and prior) could lead to type confusion when processing project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.

CVSS 3.0 · 7.3 High EPSS 1.2% KEV · Not listed
Vendors
Products
CVE-2018-19017

Several use after free vulnerabilities have been identified in CX-Supervisor (Versions 3.42 and prior). When processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.

CVSS 3.0 · 8.8 High EPSS 2.4% KEV · Not listed
Vendors
Products
CVE-2018-19016

Rockwell Automation EtherNet/IP Web Server Modules 1756-EWEB (includes 1756-EWEBK) Version 5.001 and earlier, and CompactLogix 1768-EWEB Version 2.005 and earlier. A remote attacker could send a crafted UDP packet to the SNMP service causing a denial-of-service condition to occur until the affected product is restarted.

CVSS 3.0 · 7.5 High EPSS 3.2% KEV · Not listed
CVE-2018-19015

An attacker could inject commands to launch programs and create, write, and read files on CX-Supervisor (Versions 3.42 and prior) through a specially crafted project file. An attacker could exploit this to execute code under the privileges of the application.

CVSS 3.1 · 7.3 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2018-19014

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about internals of the patient monitor, the location of the monitor, and wired network configuration.

CVSS 3.0 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-19013

An attacker could inject commands to delete files and/or delete the contents of a file on CX-Supervisor (Versions 3.42 and prior) through a specially crafted project file.

CVSS 3.0 · 5.0 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-19012

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker is able to take control of the operating system.

CVSS 3.0 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-19011

CX-Supervisor (Versions 3.42 and prior) can execute code that has been injected into a project file. An attacker could exploit this to execute code under the privileges of the application.

CVSS 3.0 · 8.8 High EPSS 2.4% KEV · Not listed
Vendors
Products
CVE-2018-19010

Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.

CVSS 3.0 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-19009

Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2018-19008

The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Abb
CVE-2018-19006

OSIsoft PI Vision, versions PI Vision 2017, and PI Vision 2017 R2, The application contains a cross-site scripting vulnerability where displays that reference AF elements and attributes containing JavaScript are affected. This vulnerability requires the ability of authorized AF users to store JavaScript in AF elements and attributes.

CVSS 3.0 · 4.8 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-19005

Cscape, Version 9.80.75.3 SP3 and prior. An improper input validation vulnerability has been identified that may be exploited by processing specially crafted POC files lacking user input validation. This may allow an attacker to read confidential information and remotely execute arbitrary code.

CVSS 3.0 · 7.8 High EPSS 1.7% KEV · Not listed
Products