Search vulnerabilities

Results 425,829

CVE-2018-14808

Emerson AMS Device Manager v12.0 to v13.5. Non-administrative users are able to change executable and library files on the affected products.

CVSS 3.0 · 6.5 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-14807

A stack-based buffer overflow vulnerability in Opto 22 PAC Control Basic and PAC Control Professional versions R10.0a and prior may allow remote code execution.

CVSS 3.1 · 9.8 Critical EPSS 3.1% KEV · Not listed
Vendors
Products
CVE-2018-14806

Advantech WebAccess 8.3.1 and earlier has a path traversal vulnerability which may allow an attacker to execute arbitrary code.

CVSS 3.0 · 9.8 Critical EPSS 4.8% KEV · Not listed
Vendors
Products
CVE-2018-14805

ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Both conditions are required to exploit this vulnerability.

CVSS 3.0 · 9.8 Critical EPSS 4.6% KEV · Not listed
Vendors
Products
CVE-2018-14804

Emerson AMS Device Manager v12.0 to v13.5. A specially crafted script may be run that allows arbitrary remote code execution.

CVSS 3.0 · 9.8 Critical EPSS 3.5% KEV · Not listed
Vendors
CVE-2018-14803

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to the attacker, but might be useful information in an attack.

CVSS 3.0 · 5.3 Medium EPSS 1.7% KEV · Not listed
Vendors
CVE-2018-14802

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly check user-supplied comments which may allow for arbitrary remote code execution.

CVSS 3.0 · 9.8 Critical EPSS 3.6% KEV · Not listed
Vendors
Products
CVE-2018-14801

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical access can enter the superuser password that can be used to access and modify all settings on the device, as well as allow the user to reset existing passwords.

CVSS 3.0 · 6.2 Medium EPSS < 1% KEV · Not listed
Vendors
CVE-2018-14800

Delta Electronics ISPSoft version 3.0.5 and prior allow an attacker, by opening a crafted file, to cause the application to read past the boundary allocated to a stack object, which could allow execution of code under the context of the application.

CVSS 3.0 · 7.8 High EPSS 1.6% KEV · Not listed
Vendors
Products
CVE-2018-14798

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. The program does not properly parse FNC files that may allow for information disclosure.

CVSS 3.0 · 5.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2018-14797

Emerson DeltaV DCS versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, R5 allow a specially crafted DLL file to be placed in the search path and loaded as an internal and valid DLL, which may allow arbitrary code execution.

CVSS 3.1 · 7.8 High EPSS 1.7% KEV · Not listed
Vendors
Products
CVE-2018-14796

Tec4Data SmartCooler, all versions prior to firmware 180806, the device responds to a remote unauthenticated reboot command that may be used to perform a denial of service attack.

CVSS 3.0 · 7.5 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2018-14795

DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable due to improper path validation which may allow an attacker to replace executable files.

CVSS 3.0 · 8.8 High EPSS 2.2% KEV · Not listed
Vendors
Products
CVE-2018-14793

DeltaV Versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, and R5 is vulnerable to a buffer overflow exploit through an open communication port to allow arbitrary code execution.

CVSS 3.0 · 8.8 High EPSS 1.0% KEV · Not listed
Vendors
Products
CVE-2018-14792

WECON PLC Editor version 1.3.3U may allow an attacker to execute code under the current process when processing project files.

CVSS 3.0 · 6.3 Medium EPSS 1.3% KEV · Not listed
Vendors
Products
CVE-2018-14791

Emerson DeltaV DCS versions 11.3.1, 12.3.1, 13.3.0, 13.3.1, R5 may allow non-administrative users to change executable and library files on the affected products.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2018-14790

Fuji Electric FRENIC LOADER v3.3 v7.3.4.1a of FRENIC-Mini (C1), FRENIC-Mini (C2), FRENIC-Eco, FRENIC-Multi, FRENIC-MEGA, FRENIC-Ace. A buffer over-read vulnerability may allow remote code execution on the device.

CVSS 3.0 · 9.8 Critical EPSS 5.4% KEV · Not listed
Vendors
Products