Search
Search Results (28 CVEs found)
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2013-5023 | 1 Ni | 5 Diadem, Labview, Labwindows and 2 more | 2025-04-11 | N/A |
The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files. | ||||
CVE-2024-10496 | 1 Ni | 1 Labview | 2025-03-04 | 7.8 High |
An out of bounds read due to improper input validation in BuildFontMap in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions. | ||||
CVE-2024-10494 | 1 Ni | 1 Labview | 2025-03-04 | 7.8 High |
An out of bounds read due to improper input validation in HeapObjMapImpl.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions. | ||||
CVE-2024-10495 | 1 Ni | 1 Labview | 2025-03-04 | 7.8 High |
An out of bounds read due to improper input validation when loading the font table in fontmgr.cpp in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q3 and prior versions. | ||||
CVE-2024-23610 | 1 Ni | 1 Labview | 2025-02-27 | 7.8 High |
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2024-23611 | 1 Ni | 1 Labview | 2025-02-27 | 7.8 High |
An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2024-23612 | 1 Ni | 1 Labview | 2024-11-21 | 7.8 High |
An improper error handling vulnerability in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. | ||||
CVE-2022-27237 | 1 Ni | 5 Flexlogger, G Web Development Software, Labview and 2 more | 2024-11-21 | 6.1 Medium |
There is a cross-site scripting (XSS) vulnerability in an NI Web Server component installed with several NI products. Depending on the product(s) in use, remediation guidance includes: install SystemLink version 2021 R3 or later, install FlexLogger 2022 Q2 or later, install LabVIEW 2021 SP1, install G Web Development 2022 R1 or later, or install Static Test Software Suite version 1.2 or later. |