CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
An improper parsing vulnerability was reported in the FileZ client that could allow a crafted file in the FileZ directory to read arbitrary files on the device due to URL preloading. |
This vulnerability could lead to denial-of-service or service crashes. Exploitation of the moxa_cmd service, because of insufficient input validation, allows attackers to disrupt operations. If exposed to public networks, the vulnerability poses a significant remote threat, potentially allowing attackers to shut down affected systems. |
A vulnerability in the “Proxy” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to manipulate the “/etc/environment” file via a crafted HTTP request. |
A vulnerability was discovered in Samsung Mobile Processors Exynos 850, Exynos 1080, Exynos 2100, Exynos 2200, Exynos 1280, Exynos 1380, Exynos 1330, and Exynos W930 where they do not properly check length of the data, which can lead to a Denial of Service. |
Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to read information in the product, to cause a Denial-of-Service (DoS) condition in MELSOFT connection, or to stop the operation of the CPU module (causing a DoS condtion on the CPU module), by sending specially crafted packets. The product is needed to reset for recovery. |
IBM Tivoli Monitoring 6.3.0.7 through 6.3.0.7 Service Pack 19 could allow a remote attacker to execute arbitrary code due to improper validation of an index value of a dynamically allocated array. |
An issue was discovered in mouse07410 asn1c thru 0.9.29 (2025-03-20) - a fork of vlm asn1c. In UPER (Unaligned Packed Encoding Rules), asn1c-generated decoders fail to enforce INTEGER constraints when the bound is positive and exceeds 32 bits in length, potentially allowing incorrect or malicious input to be processed. |
The Eaton Foreseer software provides multiple customizable input fields for the users to configure parameters in the tool like alarms, reports, etc. Some of these input fields were not checking the length and bounds of the entered value. The exploit of this security flaw by a bad actor may result in excessive memory consumption or integer overflow. |
On affected platforms running Arista EOS with Traffic Policies configured the vulnerability will cause received untagged packets not to hit Traffic Policy rules that they are expected to hit. If the rule was to drop the packet, the packet will not be dropped and instead will be forwarded as if the rule was not in place. This could lead to packets being delivered to unexpected destinations. |
IBM QRadar Suite Software 1.10.12.0 through 1.11.2.0 and IBM Cloud Pak for Security 1.10.0.0 through 1.10.11.0 could allow an authenticated user to cause a denial of service due to improperly validating API data input. |
Mattermost versions 10.8.x <= 10.8.3, 10.5.x <= 10.5.8, 9.11.x <= 9.11.17, 10.10.x <= 10.10.0, 10.9.x <= 10.9.3 fail to validate import data which allows a system admin to crash the server via the bulk import feature. |
Fastify is a fast and low overhead web framework, for Node.js. In versions 5.0.0 to 5.3.0 as well as version 4.29.0, applications that specify different validation strategies for different content types have a possibility to bypass validation by providing a _slightly altered_ content type such as with different casing or altered whitespacing before `;`. This was patched in v5.3.1, but the initial patch did not cover all problems. This has been fully patched in v5.3.2 and v4.29.1. A workaround involves not specifying individual content types in the schema. |
A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions. |
In PHP versions 8.1.* before 8.1.30, 8.2.* before 8.2.24, 8.3.* before 8.3.12, erroneous parsing of multipart form data contained in an HTTP POST request could lead to legitimate data not being processed. This could lead to malicious attacker able to control part of the submitted data being able to exclude portion of other data, potentially leading to erroneous application behavior. |
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in fontmgr may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions. |
Out of bounds read vulnerability due to improper bounds checking in NI LabVIEW in lvre!UDecStrToNum that may result in information disclosure or arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions. |
A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions. |
IBM SmartCloud Analytics - Log Analysis 1.3.7.0, 1.3.7.1, 1.3.7.2, 1.3.8.0, 1.3.8.1, and 1.3.8.2 could allow a local user to cause a denial of service due to improper validation of specified type of input. |
A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. |
A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IY8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle. |