Filtered by CWE-787
Total 11744 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-21132 2025-01-14 7.8 High
Substance3D - Stager versions 3.0.4 and earlier are affected by an out-of-bounds write vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
CVE-2025-21131 2025-01-14 7.8 High
Substance3D - Stager versions 3.0.4 and earlier are affected by an out-of-bounds write vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
CVE-2025-21130 2025-01-14 7.8 High
Substance3D - Stager versions 3.0.4 and earlier are affected by an out-of-bounds write vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
CVE-2024-13170 2025-01-14 7.5 High
An out-of-bounds write in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to cause a denial of service.
CVE-2024-13168 2025-01-14 7.5 High
An out-of-bounds write in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to cause a denial of service.
CVE-2024-13167 2025-01-14 7.5 High
An out-of-bounds write in Ivanti EPM before the 2024 January-2025 Security Update and 2022 SU6 January-2025 Security Update allows a remote unauthenticated attacker to cause a denial of service.
CVE-2025-0282 1 Ivanti 3 Connect Secure, Neurons For Zero-trust Access, Policy Secure 2025-01-14 9 Critical
A stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.5, Ivanti Policy Secure before version 22.7R1.2, and Ivanti Neurons for ZTA gateways before version 22.7R2.3 allows a remote unauthenticated attacker to achieve remote code execution.
CVE-2025-0283 1 Ivanti 3 Connect Secure, Neurons For Zero-trust Access, Policy Secure 2025-01-14 7 High
A stack-based buffer overflow in Ivanti Connect Secure before version 22.7R2.5, Ivanti Policy Secure before version 22.7R1.2, and Ivanti Neurons for ZTA gateways before version 22.7R2.3 allows a local authenticated attacker to escalate their privileges.
CVE-2024-2980 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-01-14 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2981 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-01-14 8.8 High
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2983 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2984 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2985 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258154 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2986 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258155. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2987 1 Tenda 2 Fh1202, Fh1202 Firmware 2025-01-14 8.8 High
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2489 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2490 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2488 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2487 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2485 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 8.8 High
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.