| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Elcomplus SmartPTT is vulnerable when a low-authenticated user can access higher level administration authorization by issuing requests directly to the desired endpoints. |
| Sequi PortBloque S has an improper authorization vulnerability, which may allow a low-privileged user to perform administrative functions using specifically crafted requests. |
| Sequi PortBloque S has a improper authentication issues which may allow an attacker to bypass the authentication process and gain user-level access to the device. |
| A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a drive-by attack to load the firmware on any CMS8000 device. |
| The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges. |
| Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. A low-privileged attacker could leverage this vulnerability to bypass security measures and gain unauthorized read access. Exploitation of this issue does not require user interaction. |
| Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in Privilege escalation. A low-privileged attacker could leverage this vulnerability to modify select data. Exploitation of this issue does not require user interaction. |
| Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. A low-privileged attacker could leverage this vulnerability to bypass security measures and gain unauthorized read access. Exploitation of this issue does not require user interaction. |
| Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. A low-privileged attacker could leverage this vulnerability to bypass security measures and gain unauthorized read access. Exploitation of this issue does not require user interaction. |
| The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data. |
| The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently. |
| Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. |
| Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 allows user input to be validated on the client side without authentication by the server. The server should not rely on the correctness of the data because users might not support or block JavaScript or intentionally bypass the client-side checks. An attacker with knowledge of the service user could circumvent the client-side control and login with service privileges. |
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 does not perform proper authorization and authentication checks on multiple API routes. An attacker may gain access to these API routes and achieve remote code execution, create a denial-of-service condition, and obtain sensitive information. |
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active. |
| All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization. |
| After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly. |
| Navigating to a specific URL with a patient ID number will result in the server generating a PDF of a lab report without authentication and rate limiting. |
| Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration. |
| The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation. |