| When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) when receiving certain input throws an exception. Services using said function do not handle the exception. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to crash the affected product. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |
| GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings. |
| A vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier. |
| An attacker could leverage an API to pass along a malicious file that could then manipulate the process creation command line in MDT AutoSave versions prior to v6.02.06 and run a command line argument. This could then be leveraged to run a malicious process. |
| Improper input validation in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to execute commands. |
| Five buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to initiate a denial-of-service attack and execute arbitrary code. |
| Modbus Tools Modbus Slave (versions 7.4.2 and prior) is vulnerable to a stack-based buffer overflow in the registration field. This may cause the program to crash when a long character string is used. |
| A specially crafted packet sent to the Fernhill SCADA Server Version 3.77 and earlier may cause an exception, causing the server process (FHSvrService.exe) to exit. |
| A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations. |
| A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface. |
| Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module. |
| The affected product is vulnerable to misconfigured binaries, allowing users on the target PC with SYSTEM level privileges access to overwrite the binary and modify files to gain privilege escalation. |
| An attacker may be able to inject client-side JavaScript code on multiple instances within all versions of Uffizio GPS Tracker. |
| RTI Connext DDS Professional and Connext DDS Secure Versions 4.2.x to 6.1.0 are vulnerable to a stack-based buffer overflow, which may allow a local attacker to execute arbitrary code. |
| The Weintek cMT product line is vulnerable to a cross-site scripting vulnerability, which could allow an unauthenticated remote attacker to inject malicious JavaScript code. |
| xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘bdate’ of the resource xhisvalue.htm, which may allow an unauthorized attacker to execute arbitrary code. |
| xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘edate’ of the resource xhisalarm.htm, which may allow an unauthorized attacker to execute arbitrary code. |
| xArrow SCADA versions 7.2 and prior permits unvalidated registry keys to be run with application-level privileges. |