| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in the SMTP Email Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to credentials in plaintext via a passback attack. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. |
| Bosscomm IF740 Firmware versions:11001.7078 & v11001.0000 and System versions: 6.25 & 6.00 were discovered to send communications to the update API in plaintext, allowing attackers to access sensitive information via a man-in-the-middle attack. |
| This vulnerability exists in the TP-Link Archer C50 due to presence of terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by accessing the UART shell on the vulnerable device. Successful exploitation of this vulnerability could allow the attacker to obtain Wi-Fi credentials of the targeted system. |
| CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure
of data when network traffic is being sniffed by an attacker. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| JUnit is a testing framework for Java and the JVM. From version 5.12.0 to 5.13.1, JUnit's support for writing Open Test Reporting XML files can leak Git credentials. The impact depends on the level of the access token exposed through the OpenTestReportGeneratingListener. If these test reports are published or stored anywhere public, then there is the possibility that a rouge attacker can steal the token and perform elevated actions by impersonating the user or app. This issue as been patched in version 5.13.2. |
| Due to an unsecure default configuration HTTP is used instead of HTTPS for the web interface. An unauthenticated attacker on the same network could exploit this to learn sensitive data during transmission. |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. |
| A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive information, including obfuscated safety passwords. |
| This vulnerability exists in the Tinxy smart devices due to storage of credentials in plaintext within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext credentials stored on the vulnerable device. |
| The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data.
The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources. |
| TM2 Monitoring v3.04 contains an authentication bypass and plaintext credential disclosure. |
| Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information. |
| A privilege escalation vulnerability was discovered when Single Sign On (SSO) is enabled that could allow an attacker to intercept a valid, authenticated LXCA user’s XCC session if they can convince the user to click on a specially crafted URL. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device. |
| In Unify CP IP Phone firmware 1.10.4.3, files are not encrypted and contain sensitive information such as the root password hash. |
| This vulnerability exists in the Meon KYC solutions due to transmission of sensitive data in plain text within the response payloads of certain API endpoints. An authenticated remote attacker could exploit this vulnerability by intercepting API response that contains unencrypted sensitive information belonging to other users.
Successful exploitation of this vulnerability could allow remote attacker to impersonate the target user and gain unauthorized access to the user account. |
| Kaseya Rapid Fire Tools Network Detective 2.0.16.0 has Unencrypted Credentials (for privileged access) stored in the collector.txt configuration file. |
| Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GT Designer3 Version1 (GOT2000) all versions and Mitsubishi Electric GT Designer3 Version1 (GOT1000) all versions allows a local unauthenticated attacker to obtain plaintext credentials from the project file for GT Designer3. This could allow the attacker to operate illegally GOT2000 series or GOT1000 series by using the obtained credentials. |
| An issue was discovered in Newland Nquire 1000 Interactive Kiosk version NQ1000-II_G_V1.00.011, allows remote attackers to obtain sensitive information via cleartext credential storage in backup.htm component. |