CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
An issue was discovered in Castle Rock SNMPc Online 12.10.10 before 2020-01-28. It includes the username and password values in cleartext within each request's cookie value. |
3xLOGIC Infinias eIDC32 2.213 devices with Web 1.107 allow Authentication Bypass via CMD.HTM?CMD= because authentication depends on the client side's interpretation of the <KEY>MYKEY</KEY> substring. |
An issue was discovered on Tata Sonata Smart SF Rush 1.12 devices. It has been identified that the smart band has no pairing (mode 0 Bluetooth LE security level) The data being transmitted over the air is not encrypted. Adding to this, the data being sent to the smart band doesn't have any authentication or signature verification. Thus, any attacker can control a parameter of the device. |
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network. |
ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network. |
Technicolor TC7337NET 08.89.17.23.03 devices allow remote attackers to discover passwords by sniffing the network for an "Authorization: Basic" HTTP header. |
This vulnerability applies to the Micro Air Vehicle Link (MAVLink) protocol and allows a remote attacker to gain access to sensitive information provided it has access to the communication medium. MAVLink is a header-based protocol that does not perform encryption to improve transfer (and reception speed) and efficiency by design. The increasing popularity of the protocol (used accross different autopilots) has led to its use in wired and wireless mediums through insecure communication channels exposing sensitive information to a remote attacker with ability to intercept network traffic. |
NCR SelfServ ATMs running APTRA XFS 05.01.00 do not encrypt, authenticate, or verify the integrity of messages between the BNA and the host computer, which could allow an attacker with physical access to the internal components of the ATM to execute arbitrary code, including code that enables the attacker to commit deposit forgery. |
A spoofing vulnerability exists in Microsoft Visual Studio as it includes a reply URL that is not secured by SSL, aka 'Microsoft Visual Studio Spoofing Vulnerability'. |
Due to unencrypted signal communication and predictability of rolling codes, an attacker can "desynchronize" an ABUS Secvest wireless remote control (FUBE50014 or FUBE50015) relative to its controlled Secvest wireless alarm system FUAA50000 3.01.01, so that sent commands by the remote control are not accepted anymore. |
The web application portal of the Cobham EXPLORER 710, firmware version 1.07, sends the login password in cleartext. This could allow an unauthenticated, local attacker to intercept the password and gain access to the portal. |
An issue was discovered on Moxa MGate MB3170 and MB3270 devices before 4.1, MB3280 and MB3480 devices before 3.1, MB3660 devices before 2.3, and MB3180 devices before 2.1. Sensitive information is sent to the web server in cleartext, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server. |
Some analytics data was sent using HTTP rather than HTTPS. This was addressed by no longer sending this analytics data. This issue is fixed in Texture 5.11.10 for iOS, Texture 4.22.0.4 for Android. An attacker in a privileged network position may be able to intercept analytics data. |
The Help feature in the ES File Explorer File Manager application 4.1.9.7.4 for Android allows session hijacking by a Man-in-the-middle attacker on the local network because HTTPS is not used, and an attacker's web site is displayed in a WebView with no information about the URL. |
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. The default management application is delivered over cleartext HTTP with Basic Authentication, as demonstrated by the /admin/index.html URI. |
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol. |
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. |
In BIG-IQ 6.0.0-6.1.0, services for stats do not require authentication nor do they implement any form of Transport Layer Security (TLS). |
On BIG-IP 14.1.0-14.1.0.5, 14.0.0-14.0.0.4, 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.1-11.5.8, SNMP exposes sensitive configuration objects over insecure transmission channels. This issue is exposed when a passphrase is inserted into various profile types and accessed using SNMPv2. |
On BIG-IP 13.0.0-13.1.1.4, 12.1.0-12.1.4, 11.6.1-11.6.3.4, and 11.5.2-11.5.8, SNMP may expose sensitive configuration objects over insecure transmission channels. This issue is exposed when a passphrase is used with various profile types and is accessed using SNMPv2. |