Search Results (84875 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-30472 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 9.8 Critical
Tenda AC Seris Router AC18_V15.03.05.19(6318) has a stack-based buffer overflow vulnerability in function fromAddressNat
CVE-2022-30464 1 Chatbot App With Suggestion Project 1 Chatbot App With Suggestion 2024-11-21 5.4 Medium
ChatBot App with Suggestion in PHP/OOP v1.0 is vulnerable to Cross Site Scripting (XSS) via /simple_chat_bot/classes/Master.php?f=save_response.
CVE-2022-30462 1 Water Billing System Project 1 Water Billing System 2024-11-21 5.4 Medium
Water-billing-management-system v1.0 is affected by: Cross Site Scripting (XSS) via /wbms/classes/Users.php?f=save, firstname.
CVE-2022-30460 1 Simple Social Networking Site Project 1 Simple Social Networking Site 2024-11-21 5.4 Medium
Simple Social Networking Site v1.0 is vulnerable to Cross Site Scripting (XSS) via /sns/classes/Users.php?f=save, firstname.
CVE-2022-30458 1 Automotive Shop Management System Project 1 Automotive Shop Management System 2024-11-21 5.4 Medium
Automotive Shop Management System v1.0 is vulnerable to Cross Site Scripting (XSS) via /asms/classes/Master.php?f=save_product, name.
CVE-2022-30456 1 Badminton Center Management System Project 1 Badminton Center Management System 2024-11-21 5.4 Medium
Badminton Center Management System 1.0 is vulnerable to Cross Site Scripting (XSS) via /bcms/classes/Master.php?f=save_court_rental.
CVE-2022-30429 1 Neos 1 Neos Cms 2024-11-21 5.4 Medium
Multiple cross-site scripting (XSS) vulnerabilities in Neos CMS allow attackers with the editor role or higher to inject arbitrary script or HTML code using the editor function, the deletion of assets, or a workspace title. The vulnerabilities were found in versions 3.3.29 and 8.0.1 and could also be present in all intermediate versions.
CVE-2022-30425 1 Tenda 2 Hg6, Hg6 Firmware 2024-11-21 8.8 High
Tenda Technology Co.,Ltd HG6 3.3.0-210926 was discovered to contain a command injection vulnerability via the pingAddr and traceAddr parameters. This vulnerability is exploited via a crafted POST request.
CVE-2022-30422 1 Proietti 1 Planet Time Enterprise 2024-11-21 9.8 Critical
Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter.
CVE-2022-30349 1 Sscms 1 Siteserver Cms 2024-11-21 6.1 Medium
siteserver SSCMS 6.15.51 is vulnerable to Cross Site Scripting (XSS).
CVE-2022-30329 1 Trendnet 2 Tew-831dr, Tew-831dr Firmware 2024-11-21 9.8 Critical
An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. An OS injection vulnerability exists within the web interface, allowing an attacker with valid credentials to execute arbitrary shell commands.
CVE-2022-30326 1 Trendnet 2 Tew-831dr, Tew-831dr Firmware 2024-11-21 5.4 Medium
An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The network pre-shared key field on the web interface is vulnerable to XSS. An attacker can use a simple XSS payload to crash the basic.config page of the web interface.
CVE-2022-30321 2 Hashicorp, Redhat 3 Go-getter, Openshift, Openstack 2024-11-21 8.6 High
go-getter up to 1.5.11 and 2.0.2 allowed arbitrary host access via go-getter path traversal, symlink processing, and command injection flaws. Fixed in 1.6.1 and 2.1.0.
CVE-2022-30318 1 Honeywell 4 Controledge Plc, Controledge Plc Firmware, Controledge Rtu and 1 more 2024-11-21 9.8 Critical
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
CVE-2022-30314 1 Honeywell 2 Safety Manager, Safety Manager Firmware 2024-11-21 4.6 Medium
Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS Safety Manager hardcoded credentials issue. The affected components are characterized as: POLO bootloader. The potential impact is: Manipulate firmware. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 serial interface for firmware management purposes. When booting, the Safety Manager exposes the Enea POLO bootloader via this interface. Access to the boot configuration is controlled by means of credentials hardcoded in the Safety Manager firmware. The credentials for the bootloader are hardcoded in the firmware. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize these credentials to control the boot process and manipulate the unauthenticated firmware image (see FSCT-2022-0054).
CVE-2022-30311 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30310 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30309 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30308 1 Festo 16 Controller Cecc-x-m1, Controller Cecc-x-m1-mv, Controller Cecc-x-m1-mv-s1 and 13 more 2024-11-21 9.8 Critical
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CVE-2022-30306 1 Fortinet 1 Fortiweb 2024-11-21 6.3 Medium
A stack-based buffer overflow vulnerability [CWE-121] in the CA sign functionality of FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below may allow an authenticated attacker to achieve arbitrary code execution via specifically crafted password.